Ftb-7500e, Technical specifications, Otdr – EXFO OTDR 2 User Manual
Page 188
Technical Specifications
180
OTDR
FTB-7500E
FTB-7500E
TECHNICAL SPECIFICATIONS
Model
a
FTB-7500E
Wavelengths (nm)
b
1310 ± 20/1550 ± 20/1625 ± 10
Dynamic range at 20
+s (dB)
c
45/45/45
Event dead zone (m)
d
0.8
Attenuation dead zone (m)
d
4/4.5/4.5
Distance range (km)
1.25, 2.5, 5, 10, 20, 40, 80, 160, 260, 400
Pulse width (ns)
5, 10, 30, 50, 100, 275, 500, 1000, 2500, 10 000, 20 000
Linearity (dB/dB)
b
± 0.03
Loss threshold (dB)
0.01
Loss resolution (dB)
0.001
Sampling resolution (m)
0.04 to 5
Sampling points
Up to 256 000
Distance uncertainty (m)
e
± (0.75 + 0.001 % x distance + sampling resolution)
Measurement time
User-defined (5 sec. minimum to 60 min. maximum)
Typical real-time refresh (Hz)
4
Stable source output power (dBm)
f
–1 (7400E-0023B)
Visual fault locator (optional)
b
Laser, 650 nm ± 10 nm
CW, P
out
in 62.5/125 μm: 1.5 dBm (1.4 mW)
Notes
a. For
complete
details on all available configurations, refer to the Ordering Information section.
b. Typical.
c. Typical dynamic range with a three-minute averaging at SNR = 1. Typical dynamic range at 1550 nm for the FTB-7500E-0023B configuration is 2 dB lower.
d. Typical dead zone of singlemode modules for reflectance below –45 dB, using a 5 ns pulse.
e. Does not include uncertainty due to fiber index.
f. Typical output power value at 1550 nm.