LFD-200

8

5. If you want to send a modulated signal, connect the unit to a source (such as

EXFO FOT-700 Fiber-Optic Tester, FLS-130A Fiber-Optic Light Source or
FLS-210A Variable Light Source), as illustrated below.

Note:

The recommended wavelength is 1550 nm for tone identification. If you
use another wavelength than 1310 nm or 1550 nm, the Live Fiber
Detector will still detect the signal, but the specifications are not
guaranteed.

6. Evaluate the presence and direction of light transmission.

If the traffic LED indicator located on the left-hand side is illuminated, the
traffic is coming from the right.

If the traffic LED indicator located on the right-hand side is illuminated, the
traffic is coming from the left.

A beep also indicates the presence of traffic.

7. Identify the tone.

If you have connected a source to send a modulated signal, one of the 270 Hz,
1 Hz, or 2 kHz tone LED indicator will be illuminated.

Note:

During the operation at the lowest levels of tone detection
(approximately –40 dB core power), the tone LEDs may flicker, which
indicates that the minimum range of detection was reached.