beautypg.com

2 operating the live fiber detector – EXFO LFD-200 Live Fiber Detector User Manual

Page 12

background image

Operating the Live Fiber Detector

7

2 Operating the Live Fiber

Detector

To operate the Live Fiber Detector:
1.
Choose an adapter head for the type of fiber to be tested (see Adapter Heads on

page 4).

2. Slide the adapter head into the mating slotted channel, applying a slight

downward pressure.
If you have the LFD-203 Live Fiber Detector model, be sure to place the adapter
with the indexing notch facing the front of the unit.

3. Place the fiber gently in the alignment groove of the adapter head.

4. Slide the switch upward.

OR
For hands-free operation, slide the switch upward and over to the right to lock it
in place.

Note:

Each time the switch is operated, the Live Fiber Detector performs a
self-test. During the self-test, all LEDs will illuminate and will turn off
after approximately 0.5 seconds.