beautypg.com

Thresholds – EXFO ARU-100 HPNA Test Probe User Manual

Page 11

background image

ARU-100

6

Thresholds

The Thresholds tab allows you to specify upper and
lower thresholds against which the actual
measured unit negotiated results will be evaluated.

³

Min Data Rate (Mbps) is the minimum data
rate ranging from 35 to 160.

³

Min SNR (dB) is the minimum signal-to-noise
ratio ranging from 35 to 45.

³

Max PER is the maximum packet error rate
ranging from 1E-7 to 1E-2.

³

Max Attenuation (dB) is the maximum value for the reduction in signal
strength, ranging from 5 to 55.

³

Max Noise (dBm/Hz) lists the maximum noise level values allowed in the setup
when no traffic is present on the wire. Default value is -140 dBm/Hz

To select the threshold parameters to configure:
1.
From the Configure Tests pane, press the F1, F2, or F3 key located just below

the Thresholds tab to select it.

2. Press the up/down arrows to select the desired parameter.
3. Press

to modify the parameter.

4. Use the alphanumeric keypad to enter the value you want to specify.
5. Press

to confirm the selection.