Enrg – ENMET MX-32 User Manual
Page 20
ENMET Corporation
MX32
E
NGUARD
16
15. Press + or – to select the stabilization time at start up. Press ENTER
Press + or – to
modify the time
digit by digit
▲
1.00
min
Press ENTER when
correct time is selected
▲
auT
man
Next the sensor type
will be flashing
May display:
OtH
16. Press + or – to scroll through the different types of sensor if necessary. Press ENTER
Press + or – to
modify the type
See choices below
▲
AUT
man
Press ENTER when
correct sensor type is
selected
▲
auT
man
Next the MAN or
AUT will be flashing
or
AUT
= Other, for toxic or Oxygen (for 4-20mA Sensor/Transmitter)
or
InC
= ionic, optical etc…
(not used)
EHP
or
EHP
= Combustible
(not used)
or
POnt
= Bridge
(not used)
17. Press + or – to select MAN or AUT. Press ENTER
MAN: no visual alarm, yellow LED flashing, when s/t is in calibration mode
AUT: visual alarm, yellow LED flashing, when s/t is in calibration mode
Press + or – to
select MAN or
AUT
▲
AUT
man
Press ENTER when
correct choice is selected
▲
0.120
min
Will be displayed
Press ENTER 4 times
▲
enrg
non
Next the save (update)
programming will be
flashing
18. Press + or – to select OUI (yes) or NON (no). To update the programming for the channel, Press ENTER
If you select NON and press ENTER the programming will not be updated.
If you select OUI and press ENTER the programming will be updated.
Press + or – to
select yes or no
▲
enrg
oui
Press ENTER when
correct choice is selected
▲
0
co
Next the MX32
Control returns to the
normal display mode.
19. Programming is complete the
MX32
CONTROL
display returns to normal display mode.