beautypg.com

If an electric line is damaged, If a gas line is damaged – Ditch Witch Zahn User Manual

Page 19

background image

Safety - 18

R150/R230/R300 Operator’s Manual

Emergency Procedures

CMW

If an Electric Line is Damaged

If you suspect an electric line has been damaged and you are on platform, DO NOT MOVE. Remain on
platform and take the following actions. The order and degree of action will depend upon the situation.

Warn people nearby that an electric strike has occurred. Instruct them to leave the area and contact
utility.

Raise front end and attachments and drive from immediate area.

Contact utility company to shut off power.

Do not return to jobsite or allow anyone into area until given permission by utility company.

If you suspect an electric line has been damaged and you are off platform, DO NOT TOUCH UNIT. Take
the following actions. The order and degree of action will depend upon the situation.

LEAVE AREA. The ground surface may be electrified, so take small steps with feet close together to
reduce the hazard of being shocked from one foot to the other. For more information, contact your
Ditch Witch dealer.

Contact utility company to shut off power.

Do not return to jobsite or allow anyone into area until given permission by utility company.

If a Gas Line is Damaged

If you suspect a gas line has been damaged, take the following actions. The order and degree of action will
depend on the situation.

Immediately shut off engine(s), if this can be done safely and quickly.

Remove any ignition source(s), if this can be done safely and quickly.

Warn others that a gas line has been cut and that they should leave the area.

Leave jobsite as quickly as possible.

Immediately call your local emergency phone number and utility company.

If jobsite is along street, stop traffic from driving near jobsite.

Do not return to jobsite until given permission by emergency personnel and utility company.