beautypg.com

About menu, Faults – DaySequerra Eclipse LBR4 User Manual

Page 23

background image

     LBR4  User  Manual                  

23  

About  Menu  
 

Model Number: Displays the model number of the unit.

Serial Number: Displays the serial number of this unit.

Hardware Rev: Displays the hardware revision level of this unit.

Firmware Rev: Displays the firmware revision level that is running on this unit.

Eclipse Algorithm: Displays the specific Eclipse algorithm running.

Eclipse Algorithm Rev: Version of the Eclipse algorithm running on this unit.

 
 
Faults


Although your LBR4 will provide you with years of trouble free service, occasionally problems may
occur. Below is a listing of the most common fault conditions.

CRC Error: LBR4 has encountered a CRC error in the audio stream. Check that equipment up-stream
of LBR4 is properly configured to output the correct audio stream.

PSU Failed: LBR4 has encountered a disruption in power.

Validity Error: LBR4 has encountered a validity error with the audio stream. Check that equipment up-
stream of LBR4 is properly configured to output the correct audio stream.


Bi-phase Error: LBR4 has encountered a bi-phase error with the audio stream. Check that equipment
up-stream of LBR4 is properly configured to output the correct audio stream.

No Parity Error: LBR4 has encountered a parity error with the audio stream. Check that equipment up-
stream of LBR4 is properly configured to output the correct audio stream.

Clock Error: A valid clock signal was not found or could not be recovered from the biphase mark code
on the configured interface. Check your cable connections as well as the clock source input
configuration under the I/O menu.