Diagnostics – DaySequerra Eclipse LBR4 User Manual
Page 21
![background image](/manuals/735161/21/background.png)
LBR4 User Manual
21
Diagnostics
Figure 9. Diagnostics Menu Display
Current Faults: Displays any error states that LBR4 may be in.
DSP 1 Utilization: Shows the current load on LBR4’s main 6713 DSP.
DSP 2 Utilization: Shows the current load on LBR4’s Secondary AudioExpress 6713 DSP.
LED Test: Turns on all front-panel LED indicators to verify their functionality.
Meter Brightness: Allows adjustment of LBR4’s Input and Output meters. (Default: 0)
Display Brightness: Allows adjustment of LBR4’s display output. (Default: Max)
Restore Settings: Returns all settings to their factory default values and will reboot the unit. Network
settings will not be lost.
Reboot Unit: Performs a warm boot. No settings are erased or restored to default
GPIO: A sub-menu that turns on the ALARM outputs for testing.
• GPIO Output: Allows for testing of the internal signaling circuit within LBR4. The two fields
displayed represent each output, 1 and 2, respectively. Pressing ENTER after scrolling over
each output will test the GPIO. Then turn the rotary knob to set the output ON and OFF.
• GPIO Input: Shows the current state of the GPIO inputs. The four fields of the displayed status
represent each input, 1-4, respectively. GPI – 1 represents channel 1. GPI - 2 represents
channel 2. GPI – 3 represents channel 3. GPI – 4 represents channel 4. A test can be
performed via GPIO. As each input is pulled high the screen will display 1 next to the input
number.