FAULT - Red LED indicator illuminates when NLC5.1ST has discovered a hardware fault. An error
message will be displayed on the display and fault status may be viewed under the DIAGNOSTICS
menu.

ALARM
- Red LED indicator illuminates when NLC5.1ST has discovered an alarm condition is
occurring. An error message will be displayed onscreen with the specifications on the alarm.

Display and Controls


VACUUM FLUORESCENT DISPLAY - A multi-function display will indicate current operating status of
the unit and system menus.


ROTARY ENCODER -
A stepping optical rotary encoder is used to select values or navigate the menu
system.

ENTER KEY -
Used to enter a menu or confirm a selection. To enter the main system menu, simply
press ENTER while NLC5.1ST is on the HOME screen.


HOME KEY -
A press of this button will return NLC5.1ST to the home screen or enter home screen
selection mode.

BACK KEY –
This key will return to a previous menu, or if you are entering a value, exit the field and
return the value to the last programmed state.

Rear Panel


AES INPUTS - Four 75 BNC connectors will accept the AES3 digital audio stream. For NLC5.1ST to
work properly, the following channel inputs must be maintained:

 1/2 - Left and Right Channel (Front)
 3/4 - Center and LFE
 5/6 – Left and Right Surround
 ST – Left and Right Auxiliary Stereo

AES OUTPUTS – Four 75 BNC connectors output the AES3 digital audio stream. All processed audio
is output to these connectors regardless of the input source.

AES SYNC – One 75 BNC input and one 75 BNC passive output are present for an external clock
signal. Clock recovery is possible from an AES-3, AES-11 or Word Clock signals.

HD/SDI I/O (option 01) - Two 75 BNC connectors handle HD/SDI I/O. One input port as well as one