Various process for operation modes under TS-01 mode

System operation
mode setting

Mode selection

On/Off

Auto Save setting

Time display mode

Sleep mode setting
Fill 0 setting (fill 0 before number or not)
Start-up display setting

(On: activate, Off: deactivate)

(On: not to display 0, Off: display 0)

(On: allow to customize start-up display,
Off: Default time display)

D

F

CR

ER

R

W

P

+

OK

T C D DD

ESC

K H X Y M S

PLC calendar setting

D

F

CR

ER

R

W

P

+

OK

T C D DD

ESC

K H X

Y M S

Field selection
for setting

Set the contents

Time display mode

Select yy-mm-dd/hh-mm-ss

Confirm & update the time

OK

ESC

confirm device

OK

ER

CR

F

D

P

W

K

The right four digits show 8 consecutive

displays/settings that starts from Y10

Move to the

digit to be set

Device status display

Set device's number

Y10 Y11 Y12 Y13

Y14 Y15 Y16 Y17

Y10,Y12,Y15,Y17 are On

(Depends on actual output of the PLC)

Press and hold for 3 sec.until the blinking cursor shows

K

K

X, Y, M, S

Select device

ESC

Move the bit to
desired device's
number

ER

CR

F

D

P

W

K

Forced On/Off
setting

ER

CR

F

D

P

W

Device select mode

OK

OK

ESC

The left four digits show device number

's

4.

WR mode description:

WR writing mode

P,D,F selection

Device Confirm

+

P (Program)

D (Data Register)

F (File Register)

Writing to P (Program)

in PLC.

You can press ESC

to pause writing during

TC-01-> PLC.

Setting reading range.

(default start & end

addresses is latched

area range. User can

change it.)

Writing to F

(File Register) in PLC.

You can press ESC

to pause writing during

TC-01->PLC.

Finish writing

Finish writing

Finish writing.

d1EC is the CHKSUM

of writing data.

Finish writing

d1EC is the CHKSUM

of writing data.

B

lin

k al

te

rn

at

iv

ely

Start End

+

Finish writing

Finish writing.

d1EC is the CHKSUM

of writing data.

6

DIMENSIONS & ACCESSORY

Confirm device

OK

ER

CR

F

D

P

W

K

Move to the

digit to be set

Current value

display

Set the number

K

T, C, D, DD

Select device

ESC

ER

CR

F

D

OK

OK

ESC

DD stands for 32-bit data register

(Press and hold for 3 sec.)

Use to switch between K (decimal) / H (hexadecimal) display mode.
For

will light up.

32-bit registers, use to move to display the two left-most digits.

At this time, indicator

Both timer and counter have coils & contacts monitor.

P

W

K

ESC

Device select mode

Word device

DU-01

ESC

OK

Expansion
COM Port

DVP-PLC COM1

Connecting to

(RS-232 Port)

The accessory cable connects the DU-01 (the extension COM port of figure above) and
DVP-series PLC COM1 (RS-232) port. Therefore, the DU-01 can be connected to ES/SS/EX
or SA/SX models via the cable, as well as direct installation in the extension slot of EP/EH
models.

7

ERROR

CODE

TABLE

Code

Code Explanation & Troubleshooting

Error-00

P-read error. PLC is password-locked while the TC01 has wrong or no password
key. Need unlock the password setting on PLC or set password in TC-01 via WPL.

Error-01

P-write error. PLC is password-locked while the TC01 has wrong or no password
key; or the source model unmatched the destination model.

Error-02

D-read error. Illegitimate read range (read range only available for the general data
registers of each models, not include special D)

Error-03 D-write error. The source model unmatched the destination model.
Error-04 F-read error. ES series does not have file registers.
Error-05 F-write error. The source model unmatched the destination model.
Error-06 PLC is running. Writing to P is not permitted.

Enter Set Value

Move to the digit

to be set

Current value

display

T, C, D, DD

ESC

ER

CR

F

D

OK

ESC

Enter Set Value mode

P

W

K

OK

Device number setting

ER

CR

F

D

P

W

K

For example:

Display two left-most digits
for 32-bit register.

(Press and hold for 3 sec.)

Enter Set Value & return

to monitor mode

confirm CR

OK

CR number

Specify CR number

K

select device

ESC

ER

CR

F

D

OK

Specify the expansion

unit number

Current value

display

ESC

(0,1,2...7)

Expansion unit number

32-bit

16-bit

(Press and hold for 3 sec.)

OK

P

W

K

Enter Set Value mode

Device select mode

PLC status display

Time display mode

D

F

CR

ER

R

W

P

+

OK

T

C D DD

ESC

K H

X

Y M S

PLC status switch

Device select mode