1 > detailed description of commands – Austin Hughes MCS User Manual
Page 7

UM-CV-751-MCS-Q114V1 www.austin-hughes.com
1) CAN Bus Registry
• Function
The computer registers the MCS module of LCD display(s) to CAN bus daisy chain connection.
*Registration requires when add or remove the LCD displays from the CAN bus connection.
Header
Command
ID
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Checksum
Footer
0x06, 0x4D,0x43
0x01
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x0D, 0x0A
•
Register MCS Module(s)
MAC1 :
The 1st byte of MAC address for the LCD display
MAC2 :
The 2nd byte of MAC address for the LCD display
MAC3 :
The 3rd byte of MAC address for the LCD display
MAC4 :
The 4th byte of MAC address for the LCD display
ERR :
Error code that shows the type of error that occurred
0x10
Display controller error
0x11
Serial controller error
0x12
Unsupported Command
0x13
Checksum error
0x14
Bad parameter
0x15
Unknown error
Header
Command
ID
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Checksum
Footer
0x4D, 0x43,0x06
0x01
MAC1
MAC2
MAC3
MAC4
0x00
0x00
0x0D, 0x0A
• Ack
Header
Command
ID
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Checksum
Footer
0x4D, 0x43,0x15
0x01
ERR
0x00
0x00
0x00
0x00
0x00
0x0D, 0x0A
• Nak
< 2.1 > Detailed Description of Commands
P.5