TME-EPIC-HURQM-R2V9 Revision
2.9
Page 43 of 74
Watchdog Timer
Set / Reset / Disable Watchdog Timer.
System Restart Cause
Power loss / Watchdog / External Reset.
Fail-Safe-BIOS Support
In case of a Boot failure, hardware signals tells external logic to boot from Fail-Safe-BIOS.
Flash area
1kB Flash area for customer data
Protected Flash area
128 Bytes for Keys, ID's, etc. can stored in a write- and clear-protectable region.
Board Identify
Vendor / Board / Serial number
Board Specific LEMT functions
Voltages
The SMC of the Hurricane-QM57 implements a Voltage Monitor and samples several Onboard-Voltages. The
Voltages can be ready by calling the LEMT function “Get Voltages”. The function returns a 16 Bit value divided
in Hi-Byte (MSB) and Lo-Byte (LSB).
ADC Channel
Voltage
Name
Voltage
Formula [V]
0
---
---
1
---
---
2
+V3.3A
(MSB<<8 + LSB) * 1.100 * 3.3 / 1024
3
+V0.75
(MSB<<8 + LSB) * 3.3 / 1024
4
+V1.5
(MSB<<8 + LSB) * 3.3 / 1024
5
+V1.05M
(MSB<<8 + LSB) * 3.3 / 1024
6
+V1.05S_VTT
(MSB<<8 + LSB) * 3.3 / 1024
7
+V1.8S
(MSB<<8 + LSB) * 3.3 / 1024
TS#-Events
TS# is activated by a Temperature sensor when a device reaches its critical temperature and released when the
device is back into its normal temperature range. This counter gives the User information of
Temperature/Cooling problems. This counter is cleared when the system is removed from power. The
Hurricane-QM57 monitors the CPU- and Board-temperature and does not support TS#-Events.