4 mechanical – ADLINK Hurricane-QM57 User Manual
Page 12

TME-EPIC-HURQM-R2V9 Revision
2.9
Page 6 of 74
Environmental Specifications
Operating:
Temperature range
0 … 60 °C (standard version)
-20 … 60 °C (industrial version)
Temperature change
max. 10K / 30 minutes
Humidity (relative)
10 … 90 % (non-condensing)
Pressure
450 … 1100 hPa
Non-Operating/Storage/Transport:
Temperature range
-40 … 85 °C
Temperature change
max. 10K / 30 minutes
Humidity (relative)
5 … 95 % (non-condensing)
Pressure
450 … 1100 hPa
Mean Time Between Failures
MTBF at 25°C
128,820 hours
1.4
Mechanical
Dimensions (L x W)
165 mm x 115 mm
Height
max. 40 mm on top side above PCB
max. 12 mm on bottom side above PCB
Weight
275 g
Mounting
4 mounting holes for PCB
4 mounting holes for PCI/104-Express/PC104+ extension cards
Board-to-Board Stacking
height
22 mm
Note It is strongly recommend using plastic spacers instead of metal spacers to mount
the board. With metal spacers, there is a possible danger to create a short circuit
with the components located around the mounting holes.
This can damage the board!