ADLINK MXC-6000 Series User Manual
Page 23

Introduction
11
MXC-6000
nect) connector on the front panel. The onboard digital I/O card
supports the following features:
16-CH Isolated DI
X
Logic high: 5 to 24 V
X
Logic low: 0 to 1.5 V
X
Input resistance: 2.4K @ 0.5W
X
Isolation type: photocoupler
X
Isolation voltage: 2500 V RMS
X
Interrupt source: DI channel 0 and 1
16-CH Isolated DO
X
Output Type: MOSFET transistor
X
Sink current up to 100 mA (sustained loading) or 250 mA
(peak loading) on each isolated output channel
X
Supply voltage: 5 to 35 V DC
X
Isolation type: Digital Isolator
X
Isolation voltage: 2500 VRMS
X
Flywheel diode for VDD on all DO channels
Isolated 5V DC Power Source for DO
X
Supply voltage: 5 to 0.5V DC
X
Supply current: 180 mA (maximum)
X
Isolation type: DC-to-DC transformer
X
Isolation voltage: 1000 VRMS (channel to system)
General Specification
68-pin VHDCI(Very High Density Cable Interconnect) connector
(mating with AMP 787082-7) on the front panel
Optional accessories: DIN-68S-01 and ACL-10568-1
Data transfer: programmed IO
Software Driver support: PCIS-DASK for Windows