8 hsl-ai16ao2 utility, Hsl-ai16ao2 utility – ADLINK HSL-DO32-M-N/HSL-DO32-M-P User Manual
Page 88
HSL LinkMaster Utility
75
4.2.8 HSL-AI16AO2 Utility
1. Slave Address. Shows the slave index occupied by the
module. The module occupies two consecutive indexes.
For example, when you adjust the DIP switch to 4, the
module obtains slave indexes 4 and 6.
2. Signal Type. Indicates the module’s signal type.
3. Signal Range. Allows selection of the signal range. The
utility offers four ranges including ±10V, ±5V, ±2.5V and
±1.25V for HSL-AI16AO2-M-VV. For HSL-AI16AO2-M-
AV, the signal ranges are 20 mA, 10 mA, and 5 mA.
4. Firmware Version. Shows the latest firmware version.
5. AO Function. Key in the analog output value in the text
box, then press SEND to trigger the AO. The range is
±10 V.
6. Configuration. Allows you to check if the signal range is
correct before clicking on the Start Read button. The
Configuration button allows you to save the information
and complete the configuration task.
7. Start Read. Enables the A/D conversion task to read
back the analog input values. The values are shown in
the 12th block.
8. Stop Read. Disables the A/D conversion task.