Acrosser AR-V5430FLAT User Manual
Page 25
AR-V5430FL Installation Guide
Spec
Input DC 9V~32V, Output DC 12V (main) / 5V / 5VSB, Total 90W.
Definition
A. Soft-Off Delay: The period of time from the vehicle ignition or switch being turned
off until the power off signal is generated. The delay period is programmable.
B. Soft-Off Cycle: The period of time from the power off signal being generated until
the system is off. There is only 5VSB (5V Standby) present when the system is off
(allows you to turn it on again when the vehicle is restarted)
C. Hard Off Delay: The period of time from the system being off until the 5VSB is
completely removed.
D. Hard Off Cycle: The period of time after the Hard Off Delay. The hard off cycle
completely removes the 5VSB power so that it does not drain the battery.
Mode
Mode
Soft OFF
Delay
Hard OFF
Delay
Power ON
Control
Power OFF
Control
0 (ATX)
No
No
Remote Switch
Remote Switch
1(AT)
No
No
Local Switch
Local Switch
2
5 seconds
1 minute
Ignition
Ignition /Remote
3
1 minute
5 minutes
Ignition
Ignition /Remote
4
30 minutes
2 hours
Ignition
Ignition /Remote
5
5 seconds
1 minute
Remote Switch Ignition /Remote
6
1 minute
5 minutes
Remote Switch Ignition /Remote
7
30 minutes
2 hours
Remote Switch Ignition /Remote
Special function (only supported on modes 2~7)
A. Power on retry: If the motherboard cannot be turned on normally, the
AR-PW0932V will send an “ON” pulse to the motherboard again. The
AR-PW0932V will re-try this procedure 3 times. If the motherboard still cannot be
turned on normally after 3 retries, the AR-PW0932V will turn off 5VSB and stay in
the hard off state. The status LED will display an error code (5 flashes). The
power module will keep in the state until the ignition is turned off.
B. The AR-PW0932V sends an “ON” pulse to the motherboard when the ignition is
on for more than 2 seconds.
C. The AR-PW0932V will ignore the status change of the ignition after the ON pulse
is sent to the motherboard for 3 minutes. After this period, the AR-PW0932V will
start to check its status. This can avoid an improper “OFF” process before the OS
is completely booted.
D. The AR-PW0932V will ignore the status change of the ignition and the remote
switch during the time the “OFF” pulse is sent out. This will avoid an improper ON
process before the motherboard is completely shut down.
25/39
E. Power off retry: If the motherboard cannot be shut down normally (/PSON does