beautypg.com

Test installed fitting, Check drain cdnnect1dns, Service – American Standard 2506.011 User Manual

Page 4: Caution, Everclean™ finish care instructions

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

10

TEST INSTALLED FITTING

With HANDLE (1) in OFF position, turn on WATER
SUPPLIES

[2)

and check all connections for leaks. ^

Remove AERATOR

(3).

Operate HANDLE (TJ to flush water lines thoroughly.

Replace AERATOR

(3).

CHECK DRAIN CDNNECT1DNS

Operate POP-UP KNOB (4) and fill Bidet with water.

Check that DRAIN STOPPER

(5)

makes a good seal

and retains water in Bidet. If DRAIN STOPPER

(5)

does not seal properly please refer to Troubleshooting
section in these instructions.

Release POP-UP KNOB

(4)

down and check all drain

connections and "P" trap for leaks.^ Tighten
if necessary.

11

SERVICE

CAUTION

Turn off hot and cold water
supplies before beginning.

Turn on valve and allow water supply temperatures to

stabilize. Move HANDLE to full HOT setting. Check

water temperature.

1

-

To decrease hot limit temperature setting:

■ Pull out Plug Button

(1),

loosen Handle Set Screw

(2)

and remove Handle

[3)

from Cartridge Stem

[5).

Remove

Cartridge Cover

(4).

■ Lift Setting Insert (6), rotate counterclockwise one notch

and replace. Check water temperature and repeat if

necessary. Unit is factory set at "0" [full HOT water]. As

the setting number increases, the more cold water is

supplied in the full HOT handle position.

■ Replace Cartridge Cover

I4J.

Align Handle

I3)

and tighten

Set Screw

(2).

Replace Plug Button

m

CARTRIDGE

HOTTEST

Blend control

setting 0 - setting

insert covers blend

control setting

number 1-4

COOLEST

Blend control

setting 4

TOP

TOP

12

EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean
water may also be used, if desired. IMo additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

M968936