American Standard 1340.725 User Manual
Metering faucets, Codes and standards, Product features
L19
© 2008 AS America Inc.
METERING FAUCETS
CONVENTIONAL SPOUT SINGLE VALVE
GENERAL DESCRIPTION:
Metering faucet with conventional spout and single
control. Vandal-resistant solid brass construction.
Easy-push handle. Water conserving, pressure
compensating 1.5 GPM vandal-resistant aerator. Factory
set for a maximum of 0.25 gallon flow per activation.
Replaceable cartridge. Adjustable flow cycle.
MODEL NUMBER:
1340.725 Cast Spout Single Valve, 1.5 GPM pressure
compensating, vandal-resistant aerator
Meets the American Disabilities Act Guidelines
and
ANSI A117.1 Requirements for the
physically challenged.
FOR GROUND JOINT
OR 1-1/2" O.D. SLIP
CONNECTION
131mm
(5-3/16)
93mm
(3-5/8)
102mm
(4)
54mm
(2-1/8)
130mm
(5-1/8)
141mm
(5-9/16)
51mm
(2)
33mm
(1-3/16)
MOUNTING
SURFACE
38mm
(1-1/2)
38mm
(1-1/2)
90mm
(3-1/2)
30mm
(1-1/16 D.)
CODES AND STANDARDS
These products meet or exceed the following
codes and standards:
ANSI A117.1
ASME A112.18.1
CSA B 125
NSF 61/Section 9
PRODUCT FEATURES:
• Pressure Compensating Aerator:
Provides a constant
water flow of 1.5 gpm throughout the pressure range.
• Vandal-Resistant Brass Construction and Aerator:
Durable - Excellent in high use applications.
• Automatic Shut-off:
Stops water and energy waste. Ideal for
public restrooms where uncontrolled water usage is costly.
• Meets ADA Standard:
Requires less than 5 lbs. of operating
force to initiate flow per ANSI A117.1.
• Single Supply:
For cold or tempered water.
• Adjustable Flow Cycle
• Replaceable Valve Cartridge:
Facilitates simple replacement.
• Optional Mixing Valves
(sold separately)
• Mechanical (Model # 021943-0070A)
• Thermostatic (Model # 605XTMV)
SUGGESTED SPECIFICATION
Metering faucet shall feature a single handle vandal-resistant brass construction with a replaceable valve cartridge and an
adjustable flow cycle. Shall also feature a water-conserving pressure compensating 1.5 gpm/5.7L/min vandal-resistant
aerator. Factory set to maintain flow below the maximum 0.25 gallons per cycle required by ANSI A112.18.1M. Push button
activator shall meet ANSI A117.1 Standard. Fitting shall be American Standard Model # 1340.725.002.
46mm
(1-3/4)
FLOW RATE*
VOLUME PER CYCLE (GAL)
P R E S S U R E ( P S I )
0.00
20
40
80
60
0.05
0.10
0.15
0.20
0.25