Pantilt video integration to td-h/a or b – Aiphone My-Cu User Manual
Page 7
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

PanTilt video integration to TD-H/A or B
The DE-UR adaptor connects MY-CU system
in the middle point of TD-H/A or B installation.
MYH-CU 1 MYH-CU 2
Wiring distance
From DE-UR to power supply
Between TD-H intercoms (any pair)
Diameter
0.65mm
0.8mm
1.0mm
Distance
10m
15m
20m
AWG
22AWG
20AWG 18AWG
Distance
30’
50’ 45’
Diameter
0.65mm
0.8mm
1.0mm
Distance
650m
1,000m
1,500m
AWG
22AWG
20AWG
18AWG
Distance
2,000’
3,000’
4,900’
From MY-CU to power suppiy
From MY-CU to MYH-CU #1 (2 monitors)
Diameter
1.0mm
Distance
5m
AWG
18AWG
Distance
16’
From MY-CU to PanTiit door MY-DC
Diameter
0.65mm
0.8mm
1.0mm
Distance
50 m
70m
100m
AWG
Distance
22AWG
20AWG
18AWG
165’
230’
330’
Diameter
0.65mm
0.8mm
1.0mm
Distance
35m
50 m
75m
AWG
22AWG
20AWG
18AWG
Distance
115'
160’
250’
From MY-CU to MYH-CU #2 (3 monitors)
Diameter
0.65mm
0.8mm
1.0mm
Distance
17m
25m
45m
AWG
22AWG
20AWG
18AWG
Distance
55’
80’
145’
-
7
-