beautypg.com

Aiphone PT-1210N User Manual

Wiring diagram, Kb-dar modified for motion detector interface, Instructions

background image

Door Strike

PT-1210N

(AC Transformer)

A1
A2

WIRING DIAGRAM:

Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071

KB-DAR-M Instr.

0703bkjs

Toll Free Technical Support:

1-800-692-0200

E-mail [email protected]

Motion Detector*

White

Installation Guidelines:
1. The motion detector must provide a normally open momentary contact. A Photelectric beam, pressure

pad, or remote call button can also be used to activate the video door station.

2. The KB-DAR-M works with the KB system only. Standard KB-DAR's can be used in the same system if they

are not interfaced with a remote activation device.

Note:
Only information concerning the use of the KB-DAR-M is shown here.
For complete system installation, please refer to the instruction manuals included with the video system.

KB-DAR Modified for Motion Detector Interface

The KB-DAR-M allows any standard motion detector or activation device with a normally open contact to
be interfaced with the KB-3MRD Video System. When the motion detector is tripped, the camera will turn
on and a chime will be heard at the inside monitor station(s), indicating that there is some activity near
the door station location.

- INSTRUCTIONS -

KB-DAR-M

White

A1
A2

KB-DAR

+

-

PS-2420UL

1A1
1A2

2A1
2A2

B1
B2

+

-

KB-3MRD

Yel

Org

1A1
1A2

+

-

KB-3HRD

* Or any signaling
device that provides a
normally open
momentary dry closure.

Aiphone 871802 wire

Aiphone 871802 wire

871802

Motion Detectors with N/O Contacts:
Detection Systems DS720I
Pulnix 6612
Intellisense 8140S
Ademco 1998PI
Sentrol AP750