Aiphone PT-1210N User Manual
Wiring diagram, Kb-dar modified for motion detector interface, Instructions
Door Strike
PT-1210N
(AC Transformer)
A1
A2
WIRING DIAGRAM:
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
KB-DAR-M Instr.
0703bkjs
Toll Free Technical Support:
1-800-692-0200
E-mail [email protected]
Motion Detector*
White
Installation Guidelines:
1. The motion detector must provide a normally open momentary contact. A Photelectric beam, pressure
pad, or remote call button can also be used to activate the video door station.
2. The KB-DAR-M works with the KB system only. Standard KB-DAR's can be used in the same system if they
are not interfaced with a remote activation device.
Note:
Only information concerning the use of the KB-DAR-M is shown here.
For complete system installation, please refer to the instruction manuals included with the video system.
KB-DAR Modified for Motion Detector Interface
The KB-DAR-M allows any standard motion detector or activation device with a normally open contact to
be interfaced with the KB-3MRD Video System. When the motion detector is tripped, the camera will turn
on and a chime will be heard at the inside monitor station(s), indicating that there is some activity near
the door station location.
- INSTRUCTIONS -
KB-DAR-M
White
A1
A2
KB-DAR
+
-
PS-2420UL
1A1
1A2
2A1
2A2
B1
B2
+
-
KB-3MRD
Yel
Org
1A1
1A2
+
-
KB-3HRD
* Or any signaling
device that provides a
normally open
momentary dry closure.
Aiphone 871802 wire
Aiphone 871802 wire
871802
Motion Detectors with N/O Contacts:
Detection Systems DS720I
Pulnix 6612
Intellisense 8140S
Ademco 1998PI
Sentrol AP750