beautypg.com

Electric fireplace installation instructions, Product specifications – Desa E36LBH User Manual

Page 4

background image

ELECTRIC FIREPLACE

INSTALLATION INSTRUCTIONS

Models: (V)E32L, (V)E32LB, (V)E32LH, (V)E32LBH

V)E36L, (V)E36LB, (V)E36LH and (V)E36LBH

PRODUCT SPECIFICATIONS














HEARTH DIMENSIONS

Although not mandatory, a hearth extension is suggested for

aesthetic purposes. The appliance may be raised on a wood or

non-combustible platform supporting its entire width and depth

and extending in front of the appliance as long as the louvers are

not obstructed.


NOTE: In cold climates, when installing the appliance against a

non-insulated exterior wall, outer wall must be fully insulated in

accordance with local building code.


FRAMING DIMENSIONS

Built-in installations require a framed-in enclosure constructed of

2 x 4 or heavier lumber and sized in accordance with Figure 5.

This allows the unit to slide into the opening and be nailed to the

stud space at the sides and top nailing flanges. These flanges

accept 5/8” drywall or plywood board to finish the unit flush to

the face. Optional trim accessories are available that will extend

½” over rough edge of the wall opening (see Accessories, page

21).


IMPORTANT: If installing a perimeter trim kit, you must install

shoulder screws before inserting firebox into opening. See

instructions included with the trim kit. If installing a mantel above

the firebox, you must follow clearance instructions (see
Installation Clearances, page 3).

4

7.0"

E32 = 7.0"
E36 = 8.0"

E32 = 18 3/8"

E36 = 21"

E32 = 35 3/8"

E36 = 42"

TO NAIL LOCATION

E32 = 34 5/8"
E36 = 41 1/4"

5/8"

E32 = 28 3/8"
E36 = 31 3/4"

E32 = 6 1/2"
E36 = 5 1/4"

E32 = 16 1/4"
E36 = 17 5/8"

E32 = 22 1/4"
E36 = 24 1/4"

E32 = 28 3/8"
E36 = 31 3/4"

E32 = 32 5/8"
E36 = 36 1/4"

Location

Electrical

Conduit

E32 = 32 7/8"
E36 = 36 1/2"

TO NAIL

LOCATION

E32 = 32 1/8"
E36 = 36 1/8"

E32 = 15 5/8"

E36 = 17"

1 7/8"

TOP

LEFT SIDE

RIGHT SIDE

FRONT

Location

Electrical

Conduit

E32 = 8"

E36 = 5 1/4"

E32 = 36 3/8"

E36 = 43"

E32 = 33 3/8"

E36 = 37"

E32 = 29 3/8"

E36 = 35"

ELECTRICAL

SPECIFICATIONS

Voltage:
Total Amps:
Total Watts:

Heater Rating:
Max. Bulb Rating:
Use only on 15 ampere branch circuit

120VAC, 60Hz
12.5 Amps
1500 Watts
1100 Watts
100 Watts

Figure 4 – Unit Dimensions

F

F

o

o

r

r

m

m

o

o

r

r

e

e

i

i

n

n

f

f

o

o

r

r

m

m

a

a

t

t

i

i

o

o

n

n

,

,

v

v

i

i

s

s

i

i

t

t

w

w

w

w

w

w

.

.

d

d

e

e

s

s

a

a

t

t

e

e

c

c

h

h

.

.

c

c

o

o

m

m

E32 = 34 5/8"
E36 = 41 1/4"

E32 = 32 5/8"
E36 = 36 1/4"

PLATEFORM/SUBFLOORING

Figure 5 - Framing Dimensions

E32 = 52 3/4"
E36 = 58 1/4"

E32 = 26 5/8"
E36 = 29 3/8"

E32 = 37 5/8"
E36 = 41 3/8"

11 5/8"

FOR 11 - 5/8" OF CLEARANCE

TO THE SIDE WALL
OF THE FIREPLACE

IS ALSO PERMITTED TO

HOWEVER, 10" CLEARANCE

PERPENDICULAR SIDE WALLS

THESE DIMENSIONS ALLOW

Figure 6 - Corner Dimensions

111076-01C