beautypg.com

Desa E36LBH User Manual

Page 11

background image

ELECTRIC

FIREPLACE

INSTALLATION

INSTRUCTIONS

Models: (V)E32L, (V)E32LB, (V)E32LH, (V)E32LBH

(V)E36L, (V)E36LB, (V)E36LH and (V)E36LBH


TROUBLESHOOTING

Note: Before trouble shooting the system, make sure the power

to the circuit from the breaker or fuse panel is turned ON.

The three most common causes of a malfunctioning heater are:

1. Tripped circuit breaker or blown fuse.

2. Loose or burned out light bulb.

3. Obstructed or clogged fan blower.



OBSERVED PROBLEM

No operation or indicator light at

power/ heater switch.

Poor flame motion; flame pattern is

sporadic or devoid in viewing area.

Dull flame appearance or inactive

ember bed effect.

No heat or intermittent heat output.

(If equipped with a heater)


POSSIBLE CAUSE

1. No power to appliance.

2. Defector switch lamp.

3. Defective wiring.

1. Tangled or loose flame pennants.

2. Obstructed or clogged fan blower.

3. Damaged or dislodged fan blower wheel.

1. Burned out or loose light bulb.

2. Broken lamp fixture.

3. Loose or missing reflective ribbons.

1. Obstructed heater blower.

2. Burned out heat element or blower fan.

3. Defective heater switch or wiring.


REMEDY

1. Check circuit breaker or fuse.

2. Replace defective switch. See Servicing

Control Panel, page 14.

3. Check connections from main power

harnesses to terminals on control panel.

See Servicing Control Panel, page 14.

1. Inspect flame pennants untangle or

replace if necessary. See Servicing Flame
Pennants,
page 17.

2. Check fan blower for debris; vacuum

areas around blower wheel and remove

any obstructions. See Maintaining
Motors
, page 13.

3. Remove and inspect fan blower housing

See Servicing Fan Blower, page 16.

1. Inspect light bulbs; tighten or replace

light bulbs as necessary. See Replacing
Light Bulbs
, page 13.

2. Remove and replace broken lamp fixture.

See Replacing Lamp Fixtures, page 17.

3. Inspect reflective ribbons; Reattach or

replace as necessary. See Replacing
Reflective Ribbons
, page 18.

1. Clear heater fan of debris or blockage;

vacuum area around blower intake and

remove any obstructions in the discharge

area. See Maintaining Motors, page 13.

2. Remove and replace blower heater

assembly. To access and remove see
Optional Heater Accessory, page 8.

3. Inspect wiring connections from switch

to blower. Replace switch if defective.

See Servicing Control Panel, page 14.

11

Note: For additional help, visit DESA Technical Service web
site at www.desatech.com

F

F

o

o

r

r

m

m

o

o

r

r

e

e

i

i

n

n

f

f

o

o

r

r

m

m

a

a

t

t

i

i

o

o

n

n

,

,

v

v

i

i

s

s

i

i

t

t

w

w

w

w

w

w

.

.

d

d

e

e

s

s

a

a

t

t

e

e

c

c

h

h

.

.

c

c

o

o

m

m

111076-01C