Installation of wall-mounting plate – Amcor AOM 183HX User Manual
Page 7
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Fix with a tapi
/1 Exterior
Fig3
Installation of wall-mounting plate
Fix the wall-mounting plate firmly on the wall with screws.Make
sure of the leveling of the place. Slanted wall-mounting plate
might jeopardize the smooth discharge of condensed water.
1. Drill holes on the wall
Drill holes places slightly below the wall-mounting plate,with
hole diameter of 65mm and the outer
edge of the hole 5-10mm lower (
Fig3) so that the condensed water
can smoothly flow out. Cut the
waiicap-
wall penetrating pipe to proper
length according to the thickness
of the wall(3-5mm longer than
the wall thickness)and insert the pipe as indicated in Fig 4.
2. Installation of drain pipe
Install the pipelines of the indoor unit in accordance with the
direction of the wall holes.
Wrap tightly the drain pipe
and the pipelines with tape.
Make sure that the drain pipe
is underneath the pipelines ,
(Fig 4)(When the drain pipe
passes the room interior, so me
condensed water might occur to
high).
3. Installation of indoor unit pass
the connection wires,connecting
pipelines and drain pipe through
the wall hole.Hang the indoor unit
pjg
5
Top hooks