Self DiagnosisFuntions

Our company has provided the thoughtful services for customers, and

the air conditioner had been installed self diagnosis system to display

the code for failure.

(1) Indoor unit fault shows as following:

Failure

Failure code

Communication failure

F

1

Failure of room temperature sensor.

F

2

Failure oftube-exit temperature sensor

F

3

Failure oftube-entry temperature sensor

F

3

Failure oftube-midpointtemperature sensor

F

3

Failure of PG fan

F

4

(2) Outdoor unit fault shows as following:

Fault

Fault code

Fault ofoutdoor unit transducer module

protecting.

P

2

Outdoor unit AC input too big.

P

3

Outdoor unit compressor exhaust temperature

too

high,

outdoor

environment

temperature

ultra warm, compressor outer cover temperature

switch disconnection .

P

4

The outdoor machine direct current bus bar

is unusual in voltage.

P

7

Fault of lack refrigerant or fault of reversing

valve.

P8

Faultoftheoutdoor temperature sensor.

F6

Fault of outdoor unit drive, fault of compressor

start.

FC