ELECTRICAL CONNECTION BETWEEN

OUTDOOR AND INDOOR UNIT

ELECTRICAL REQUIREMENTS

Electrical wiring and connections should be made by qualified electricians and in accordance

with local electrical codes and regulation.The air conditioner units must be grounded.

The air conditioner units must be connected to an adequate power outlet from a separate

branch circuit protected by atimedelay circuit breaker, as specified on unit's nameplate.

Voltage should not vary beyond ± 10% of the rated voltage.

1 .Remove the power supply cable that is connected to the indoor unit!

2

.

To connect the indoor units to the outdoor units,use the foiiowing eiectrical cabies.

Electrical connections:

Power input cable: 1 group 3wiresX14AWG

cable between indoor and

outdoor units:

2 group 4 wiresX14AWG(some modeis are 2 group 2 wiresX14AWG)

3. Prepare the cable ends for the power input and for the cables between outdoor and indoor

units as shown in figure 3a and 3b respectively.

4. Connect the cable ends to the terminals of the indoor and outdoor units , as show in fig4, figS.

Please select corresponding connection according to the different indoor units.

5.Secure the multiple wire power cable with the cable clamps.

•Power input cable

L«25m(81.9673FT)

U25m(81.9673FT)

L«25m(81.9673FT)

8

mm

(0.315inch).

J

100mm

(3.937inch)

Fig

12

8

mm

(0.315inch)

40mm

_wR

(1.575inch)