INSTALLATION

Do not attempt to install your intercom system until you have read and thoroughly understood the installation pro­

cedure. Aiphone’s warranty is void if system is installed in a manner other than described in this manual.

LAM-1

LAM-3

(T) Battery cover.

^

@

Battery compartment. Place four

IM

volt C batteries

in the indicated direction.

(

3

} Terminal block;

1 , 2 , 3 : sub station number

E : for common communication

+, —

: for power supply (not required when using

batteries)

(?) Volume control for call tone. Adjust to desired level

using screw driver.

WALL MOUNTING INSTALLATION

1) Attach mounting bracket to wall or box with supplied

screws.

2) Mount station upon the mounting bracket.

LA-D INSTALLATION

(1) Attach the unit to single gang box with the

supplied 2 screws.

(2) When mounting to wall, conductors may

be pulled out either from top or bottom

of the back case.

As shown, remove the

outlet part of the case

when passing

conductors through

the top.

WIRING

Two conductors are required from master to each sub. Connect 1 and E terminals on master to 1 and E terminals on

sub #1, 2 and E terminals on master to 1 and E terminals on sub #2, etc. Do not remove the shorting link attached to termi­

nals on subs LA-A, LA-AN and LA-D.

Refer to the chart below and select the proper wire gauge to meet your requirements.

AWG WIRE SIZE

24 AWG

22 AWG

20 AWG

18 AWG

DISTANCE

400'

650'

1000'

1600'

DIAMETER OF WIRE

0.5 mm

0.65 mm

0.8 mm

1.0 mm

DISTANCE

120 m

200 m

300 m

480 m

This manual is related to the following products: