beautypg.com

Accessing unit components – Carrier P User Manual

Page 5

background image

5

ACCESSING UNIT COMPONENTS

ACCESSING INDOOR-AIR SECTION
COMPONENTS (UNITS WITH LATERAL
DUCT ACCESSORY)

REMOVE LATERAL DUCT EXTENSION

ACCESSORY ONLY ON UNITS EQUIPPED WITH
THE LATERAL DUCT

1. Remove the 2 top screws that secure the lateral

duct plenum to the top of the lateral duct exten-
sion. See Figure 8.

2. Locate and remove the 2 bottom bracket screws

(located opposite extension duct) that secure the
lateral duct plenum to the bracket flange. See
Figure 8.

3. Carefully lift the plenum up and away from front

panel and duct extension.

ACCESSING INDOOR-AIR SECTION
COMPONENTS (UNITS WITHOUT
LATERAL DUCT ACCESSORY)

REMOVE THE DISCHARGE DECK ASSEMBLY

1. Remove the front panel. Refer to Remove Front

Panel section and Figure 4.

2. Remove discharge screen screw using a

5

/

16

-in. nut

driver. See Figure 9.

3. Remove the discharge deck assembly screws using

a

5

/

16

-in. nut driver. See Figure 9.

4. Gently pull the deck/grille up and away from the

unit.

5. Reassemble by reversing steps above.

ACCESSING THE HEATER ASSEMBLY — Once the

discharge deck assembly is removed, the Heater
Assembly should now be accessible. See Figure 10.

1. Using pliers, carefully remove all wires connected

to the heater assembly. Label each wire for ease of
re-assembly.

2. Gently pull the heater assembly up and away

from scroll. See Figure 11.

3. Reassemble by reversing steps above.

ACCESSING OUTDOOR-AIR SECTION
COMPONENTS

REMOVE THE GUSSETS (See Figure 12)

1. Remove the 2 screws on each side that secure the

gussets to the partition.

2. Remove the 2 screws that secure the gussets to

the plastic condenser orifice and remove the
gussets.

POWER
CORD
ACCESS
COVER

POWER
CORD

CONTROL
BOX
SCREWS

GE WALL
SLEEVE
HOLES

AMANA, TRANE
(SLOTTED
HOLES) WALL
SLEEVE HOLES

VARIOUS ATTACHMENT

HOLE LOCATIONS

CARRIER, BRYANT
WALL SLEEVE
HOLES

FIGURE 6 — CONTROL BOX COVER

FIGURE 7 — PTAC UNIT TO WALL