MOUNTING

Mounting 3-gang box
bracket

’’"^9

Front^anei

MY-EA/FA

Screwdriver fl Tamper-proof
supplied ^ screw

WIRING

/"

83.5mm

_

Four screws 3-5/16”

Two screws supplied

attached

★ Before wiring on MY-EA/FA, make sure using video monitor is not

powered.

1. Loosen the front bottom screw using supplied screwdriver, and lift off

front panel.

2. Loosen 2 screws on MY-E/VFA to separate mounting bracket.
3. Attach the bracket to 3-gang box ring with 57mm, 2-1/4" depth

secured. Note UP-direction marking.

4. Connect 2 parallel wires on non-polarized At, A2 terminals with

secured insulation.

5. Mount unit on mounting frame and reattach front panel.
★ Do not apply any sealant around MY-E/VFA front panel, as openings

are provided for ventilation.

OPERATIONS

Wiring is non-polarized with 2 parallel wires on At, A2 terminals
of MY-E/VFA.

Wiring distance: MY-EA/FA to Video-monitor MY-1CD ,etc.

Diameter

0.65mm

1.0mm

Distance

50m

100m

AWG

Distance

22AWG

^165'

18AWG

330'

MY-1CD or
MYW-P1L (LEF)

MY-EA or MY-FA

B

MY-CU,MY-2CD,

j (door 1) MYW-P3CB (IE-8MD,

I

TD-H. etc.)

(door 2) or MYW-P3L(LEF)

The red LED is lit to locate call button, day or night. A single
push of Call button activates inside video monitor, as well as
a 4 or 2-tone chime (or other). When inside station replies,
talk handsfree.

Poor lighting conditions:

The MY-E/VFA’s infrared illumination will light the image of
the caller when positioned within 50cm, 20" in front of the
camera, and will see in near darkness (1 Lux of light).

TECHNICAL PRECAUTIONS--------------

MY-EA/FA has a camera angle presetting feature, programmable on inside

video monitor. Refer to each Manual of MY-1 CD, MY-2CD, etc.

•installation location:

The MY-E/VFA is weather resistant, but for best results it should be protected
from direct weather conditions. An eave or overhead cover is recommended to
protect it from direct rainfall.

•Temperature;

The MY-E/VFA is rated to operate at temperatures between -10° and 60°C (14°

I

SPECIFICATIONS ---------------------------

and 140°F). When the outside temperature lowers rapidly, the camera lens may
fog up slightly, causing a blurry picture at the inside monitor. The ventilation
openings will allow the moisture to evaporate, and the picture will return to
normal.

• Cleaning:

Clean the unit with a soft cloth and neutral household cleanser. Do not use an
abrasive cleaner or cloth.

Power source
Camera unit
Scanning lines
Image viewing area

Minimum

illumination

Dimensions & weight

Pan/till viewing area shown by dotted line

28cm {11")

Camera is powered from monitor unit
CCD camera
525 lines
at 50 cm, 20" from camera
Vertical 90cm, 3'. Horizontal 180cm, 6’
(140cm, 47" in still position) when panned and tilted fully
1 Lux at 50cm, 20" from camera
MY-EA/FA
162mm high x 115mm wide x 12.5mm deep.
Approx. 400g. (0.88 lbs.)
H6-3/8"xW 4-1/2" xD 1/2".
Recessed 43mm, 1-11/16",

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. 11 this equipment does cause harmful inteference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or reiocate the receiving antenna. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Increase the separation between the equipment and receiver. • Consult the dealer or an experienced radio/TV technician for help.

WARRANTY

Aiphone warrants its products to be free from defects of material and workmanship under norma! use and service for a period of two years
after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination
shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision whether there is a
defect in materials and/or workmanship; and whether or not the product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of

instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover
batteries or damage caused by batteries used in connection with the product.

This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone.
Aiphone will not be responsible for any costs incurred involving on site service calls.

-I-
•i*
-i*

-i*

-i-

Aiphone Co., Ltd. Nagoya, Japan
Aiphone Corporation, Bellevue, WA, USA

MY-EA/FA-I (E) 0596B

COMMUNICATION SYSTEMS

® AIPHONE

— HOME, BUSINESS, INDUSTRY.

Printed in Japan (E)

This manual is related to the following products: