Aiphone MY SERIES MY-EA User Manual
Alphone, My-ea my-fa, My series pantilt video door stations
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
83814600 0596®
® AlPHONE
MY Series
PanTilt VIDEO DOOR STATIONS
Models:
MY-EA
MY-FA
INSTALLATION & OPERATION MANUAL
SYSTEM OUTLINE & FEATURES---------------------------------
MY-EA & MY-FA are semi-flush mount pan and tilt video door stations, which
can be used with any Aiphone MY video system (MY-1CD, MY-2CD, MY/IE,
MY/TD-H. MY/LEF).
PACKAGE CONTENTS
For 1 entry;
MY-1CD MY-CU MYW-P1L
Connecting
Terminals
For 2 or max. 3 entries;
MY-2CD MYW-P3CB MYW-P3L
Dl
¡5
-jJ
.J
A1.A2
1A1.1A2
A1.A2
1A1.1A2
1A1.1A2
1A1, 1A2
2A1.2A2
2A1.2A2
2A1.2A2
3A1.3A2
3A1.3A2
' PanTilt video door station
(MY-EA or MY-FA)
’ Tamper-proof screwdriver
• Packet of screws
• Installation & Operation Manual
FEATURES
• Audio, video, and PanTilt control on 2 wires
• Pan and tilting of door camera
• 100m, 330' from camera to monitor on 1.0mm dia.,
18AWG wire
• Extended distance to 300 m, 980' with MYW-BA adaptor
(using 1.2mm dia., 16AWG PE jacketed wire)
• Can replace an existing doorbell using the same wire
(remove existing transformer)
LAYOUT EXAMPLE
MY-FA
MY-2CD MYH-2CD MYH-2CD
Refer to the Installation & Operation manual packed with
main monitor or adaptor.
NAMES AND FUNCTIONS
MY-FA
MY-EA
The MY-EA/FA, when measured at 50 cm, 20" from the camera,
views an area of 51 cm, 20" vertically by 72 cm. 29" horizontally.
On any and every inside monitor, operate Pan/tilt control pad to
maximize viewing area, and Backlight button to view dimly lit or
strongly backlit areas.
I
INSTALLATION & WIRING
Wiring
Use 2-conductor (parallel) cable.
Coaxial cable or 2 separate wires
should not be used.
Parallel conductor cable
................... YES
(Extra wires)
When existing chime wires are used, it is possible that the wires may
contain AC voltage current. Locate and remove the bell transformer
before actually connecting MY-EA/FA.
Extra pair(s) in the installed cable can
affect image quality, and must be
terminated with a 120 ohm resistor at I
each end of wires on both MY-EA/FA '
and inside monitor(s).
my
;“’
- - - - - - - - - - ®
ty—- - - - - - - - - - vtf
S|A1B-- - - - - - - - - - - -
III A2[^
Installation
MY-EA/FA employs a CCD
camera, and its performance can
be affected by bright direct light,
such as strong sunlight, gate light
or street or porch light which is
directed into the camera lens. Use
backlight button to compensate
for silhouetted images.