Drive error code during rebuild, Table 8: error code meanings – Ciprico 6500 User Manual
Page 81

6500 Disk Array User’s Guide
21020690 B
Chapter 4 Maintenance, Troubleshooting & Hardware Replacement
Initiating a Rebuild
Page 4 - 27
Drive Error
Code During
Rebuild
If a drive
other
than the drive being rebuilt encounters an error during the
rebuild operation, the error code shown below appears, with the “X” position
displaying the number of the affected drive:
If a drive being rebuilt encounters an error during the rebuild operation, the
error code shown above appears
without
the “X” drive identifier displayed.
Note
This type of error is most often some type of media error.
Code in this message is read as follows:
The failed drive should be replaced immediately.
If the previous message is ignored, the failed drive not replaced, and a Reset
started, a second message is displayed at the completion of the Reset. This error
message should be ignored.
Code
Meaning
Hardware Error (Sense Key)
Write Fault (Additional Sense Code)
Drive Not Ready (Additional Sense Code Qualifier
)
;
Number of Failed Drive (Field Replacement Unit number)
Table 8: Error Code Meanings