Disabling a Failed Disk Drive
Page 4 - 23
Disabling a
Failed Disk
Drive
This procedure allows you to disable one drive in the array. The array stops
operations on the selected drive and allows it to be physically removed.
Note
The array prevents any drive from being disabled if another drive
in the array is currently failed or disabled.
The procedure in the following example disables Drive 5.
1.
Press the down arrow on the display/operation panel, then press the
right or left arrows until the
)81&7,21 6(/(&7'5,9(6 menu is
displayed.
2.
Press the down arrow.
3.
Press the right or left arrows until the
',6$%/( '5,9( menu is
displayed.
4.
Press the down arrow.
5.
Press the right or left arrows until the desired drive number (e.g., 5) is
displayed.
6.
Press SELECT. The selected drive is disabled.