ZZ Mode Timing

[30, 31]

Timing Diagrams

(continued)

t

ZZ

I

SUPPLY

CLK

ZZ

t

ZZREC

ALL INPUTS

(except ZZ)

DON’T CARE

I

DDZZ

t

ZZI

t

RZZI

Outputs (Q)

High-Z

DESELECT or READ Only

Notes:

30. Device must be deselected when entering ZZ mode. See

Truth Table

[4, 5, 6, 7, 8]

on page 9

for all possible signal conditions to deselect the device.

31. DQs are in high-Z when exiting ZZ sleep mode.