beautypg.com

Cabletron Systems FRX6000 User Manual

Page 79

background image

Trap Messages

3-29

Configuring the Trap Table

LLC/2 FRMR Rcvd, IFLD too long

742

The remote device received an I frame that was too long, and returned a Frame
Reject.

Severity

Major (Level 2)

LLC/2 FRMR Rcvd, Invalid Command

743

The remote device received an invalid command or response, and returned a
Frame Reject.

Severity

Major (Level 2)

LLC/2 FRMR Sent, IFLD not permitted

744

The remote device sent an I frame when it was not permitted, and a Frame Reject
was returned.

Severity

Major (Level 2)

LLC/2 FRMR Sent, Invalid Nr

745

The remote device sent an invalid N

(R)

, and a Frame Reject was returned.

Severity

Major (Level 2)

LLC/2 FRMR Sent, IFLD too long

746

The remote device sent an I frame that was too long, and a Frame Reject was
returned.

Severity

Major (Level 2)

LLC/2 FRMR Sent, no reason

747

Self-explanatory.

Severity

Major (Level 2)

LLC/2 FRMR Rcvd, no reason

748

Self-explanatory.

Severity

Major (Level 2)

Excessive Link CRC errors

759

Self-explanatory. The line will be shut down and reestablishment will be retried
once every minute.

Severity

Major (Level 2)

SDLC Transmit link error

761

Self-explanatory. The line will be shut down and reestablishment will be retried
later.

Severity

Major (Level 2)

This manual is related to the following products: