Cabletron Systems FRX6000 User Manual
Page 79

Trap Messages
3-29
Configuring the Trap Table
LLC/2 FRMR Rcvd, IFLD too long
742
The remote device received an I frame that was too long, and returned a Frame
Reject.
Severity
Major (Level 2)
LLC/2 FRMR Rcvd, Invalid Command
743
The remote device received an invalid command or response, and returned a
Frame Reject.
Severity
Major (Level 2)
LLC/2 FRMR Sent, IFLD not permitted
744
The remote device sent an I frame when it was not permitted, and a Frame Reject
was returned.
Severity
Major (Level 2)
LLC/2 FRMR Sent, Invalid Nr
745
The remote device sent an invalid N
(R)
, and a Frame Reject was returned.
Severity
Major (Level 2)
LLC/2 FRMR Sent, IFLD too long
746
The remote device sent an I frame that was too long, and a Frame Reject was
returned.
Severity
Major (Level 2)
LLC/2 FRMR Sent, no reason
747
Self-explanatory.
Severity
Major (Level 2)
LLC/2 FRMR Rcvd, no reason
748
Self-explanatory.
Severity
Major (Level 2)
Excessive Link CRC errors
759
Self-explanatory. The line will be shut down and reestablishment will be retried
once every minute.
Severity
Major (Level 2)
SDLC Transmit link error
761
Self-explanatory. The line will be shut down and reestablishment will be retried
later.
Severity
Major (Level 2)