beautypg.com

Cabletron Systems SPECTRUM FRX6000 User Manual

Page 73

background image

Trap Messages

3-23

Configuring the Trap Table

DLCI “n” Frame Relay Header Invalid

541

The header contained an invalid DLCI.

Severity

Minor (Level 3)

Action

Check the conÞguration record for the port.

DLCI “n” PVC does not exist

542

Self-explanatory.

Severity

Minor (Level 3)

Action

Create a PVC record.

DLCI “n” Frame Discarded—CIR

543

A frame was discarded, probably because the excess burst size (B

E

) was exceeded.

Severity

Minor (Level 3)

Action

The frame must be resent.

DLCI “n” frame relay PVC deleted

545

Self-explanatory.

Severity

Informational (Level 4)

DLCI “n” frame relay PVC connected

546

Self-explanatory.

Severity

Informational (Level 4)

DLCI “n” Data Received on Inactive PVC

547

One end of the PVC is probably not up.

Severity

Minor (Level 3)

Action

Check both ends of the PVC.

DLCI “n” No STATUS ENQ Received

548

No Status Enquiry was received when one was expected.

Severity

Minor (Level 3)

Action

Check the remote device.

LLC Interface File Upd: LLC2IPAR.DAT

561

The LLC2 Interface Þle has been updated.

Severity

Informational (Level 4)

This manual is related to the following products: