beautypg.com

Cabletron Systems SPECTRUM FRX6000 User Manual

Page 61

background image

Trap Messages

3-11

Configuring the Trap Table

PAD Link Failed

413

Self-explanatory.

Severity

Major (Level 2)

Action

Check the async PAD port and its cables for proper operation and
secure connection.

Beginning of Congestion

414

The level of Maximum Congestion speciÞed in the Node Defaults record has been
exceeded, and no more events will be put into the event buffer until the Minimum
Congestion level (also speciÞed in the Node Defaults record) has been reached.

Severity

Informational (Level 4)

Action

If this occurs frequently, you may want to increase the level of
Maximum Congestion speciÞed in the Node Defaults record.

End of Congestion, “n” events lost

415

The Minimum Congestion level has been reached. (See event 414, above.)

Severity

Informational (Level 4)

PAD Autocall Retries Exhausted

416

The async PAD retry timer has expired without a connection being established.

Severity

Minor (Level 3)

Action

None; however, if this occurs with any frequency, you may want
to increase the timer (Retry Count) or check the remote async
device for problems.

Frame Relay Link Failed

417

The physical link is down.

Severity

Critical (Level 1)

Action

Check the cables for secure connections and proper operation.

PU Status p = “n” stn = 0x”n” status = “n”

426

The SDLC PU status has changed.

Severity

Major (Level 2)