Out of service proteqion, Return the unit to service after storage, Out of service protection – Generac Power Systems Air-cooled Recreational Vehicle Generator 9734-3 User Manual
Page 16
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Generac NP- MAJOR SERVICE MANUAL To obtain a service manual for your generator, order it from DRIVE BELTS The engine drives the generator rotor by means of a pulley and drive belt arrangement. The drive train, drive belt and pul the factory. If you suspect that drive belt tension is incorrect, contact an authorized service facility. OUT OF SERVICE PROTEQION If you cannot exercise the generator every seven days and it is to be out of service longer than 30 days, prepare the gen erator for storage as follows: • Start the engine and let it warm up. • Close the fuel shutoff valve in the fuel supply line and let the engine “run out of fuel.” • While the engine is still warm from running, drain the oil com pletely. Refill the crankcase with SAE10W-30 oil having an • Attach a tag to the engine indicating the viscosity and clas- sification of the oil in the crankcase. • Remove spark plugs and pour about two or three table spoons of clean, fresh engine oil into spark plug threaded • Remove the battery and store in a cool, dry room on a wooden board. Never store the battery on any concrete or • Clean and wipe the entire generator. RETURN THE UNIT TO SERVICE AFTER STORAGE To return the unit to service after storage, proceed as follows; • Check tag on engine for oil viscosity and classification. Verify that the correct recommended oil is used in the • Check battery. Fill all cells to the proper level with distilled water. DO NOT USE TAP WATER IN THE BAHERY. Recharge battery to 100% state-of-charge, or, if defective, • Turn OFF all electrical loacte, then start the engine. • Let the engine warm up. • Apply electrical loads to at least 50% of the unit’s rated wattage capacity. • Mien the engine is thoroughly warmed, shut it down. THE GENERATOR IS NOW READY FOR SERVICE. R e c r e a t i o n a l V e h i c l e G e n e r a t o r 16
your deaier/distrttxitor or contact the factory. Be sure to iden
tify your unit’s MODEL NUMBER and SERIES.
leys are warranted for the life of the generator. Drive belt
tension was properly adjusted before the unit was shipped from
API classification “For Service SP
openings. Crank engine several times to dtetribute oil, then
iristaU and tighten spark plugs. ,
wooden floor.
engine. If necessary, drain and refill with proper oil.
replace the battery.