Additjon of air conditioning, Combustible floor installation, Subbase for combustible floor – Sears 9MPD User Manual
Page 36: Н361, Caution
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

one side of furnace, require a standoff filter rack, see
Figure 36,
available from your distributor.
CAUTION
If
filters
are
only
suitable
for
heating
application,
advise
homeowner that filter size may need to be increased if air
conditioning is added.
Additjon Of Air Conditioning
When a refrigeration coil is used in conjunction with this unit, it
must be installed on the discharge side of the unit to avoid con
densation on the heat exchanger. The coil installation instructions
must be consulted for proper coil location and installation proce
dures. With a parallel flow arrangement, dampers must be
installed to prevent chilled air from entering the furnace. If manu
ally operated dampers are used, they must be equipped with a
means to prevent operation of either unit unless the clamper is in
full heat or full cool position.
A3" clearance is required on the right side of the furnace in order
to run the condensate drain line. Copper, iron or plastic tubing
may be used for the condensate drain line.
Downflow Furnace Installation
Non-Combustible Floor Installation
Fabricate a plenum to the dimensions given in
Table 8,
for the fur
nace outlet. Plenum should be flanged, approximately ^/
4
" for
support.
Note: The three{3) screws in the top panel of the furnace next to
the duct flange MUST be removed to provide serviceability of the
primary heat exchangers in the downflow installation
1. Position plenum through the floor and set the furnace over
the opening in the floor. If necessary, grout around the base
to seal air leaks between the base and the floor.
Combustible Floor Installation
FIRE HAZARD
Failure to install unit on noncombustible subbase can
result
in
death,
personal
injury
and/or
property
damage.
Place
furnace
on
noncombustible
subbase
on
downflow
applications,
unless
installing
on
non-com
bustible flooring.
Subbase for Combustible Floor
NOTE
: The three(3) screws in the top panel of the furnace next to
the duct flange MUST be removed to provide serviceability of the
primary heat exchangers in the downflow installation
Note: When using the subbase for combustible floors, the dis
charge air duct flanges on the furnace MUST be broken down to
provide proper fit up to the subbase. Use duct pliers to bend the
duct flanges flat onto the furnace casing. DO NOT bend the duct
flanges inward (toward the heat exchangers) as air flow restric
tions may occur.
The Subbase for Combustible Floors
MUST
be used when a
downflow furnace is set on a combustible floor, even when the fur
nace is installed on a coil box.
1. Cut the opening in the floor according to
Table
8
. The hole
in the floor must be cut to the dimensions listed in
Table
8
since the base is equipped with locating tabs that center the
base over the opening.
The opening in the base is IV
4
" shorter and iVs " narrower than
the recommended size of the opening in the floor. This is done to
maintain clearance between the floor and the plenum.
2.
Fabricate the plenum to the dimensions given in
Table 8.
Note that the dimensions given are outside dimensions.
Н361
44001
1114
00