beautypg.com

Sears 580.32601 User Manual

Page 3

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

TABLE OF CONTENTS

WARRANTY

RULES FOR SAFE OPERATION

SPECIFICATIONS....................

NOMENCLATURE ...... ............

WIRING DIAGRAM ............... .

INSTALLATION OF STAND-BY

POWER SYSTEMS..........

REPAIR PARTS ......... ...........

Section 1 — Preparation For Use

Alternator Unpacking and Remova

From Shipping Skid.................

Parts Shipped With Alternator „ , . .

Wheel Kit Installation .................. ..

Lubrication......................................
Battery Installation..............
Battery Connections ......................
Fill Fuel Tank,,...,............................
Install Fuel Tank ...........................

Cord Sets for 120 Volt, 15 Amp OutI
Optional Wiring Connections - 240

Connector Plug........................

Optional Wiring Connections -120

30 Amp Connector Plug ....... „

Grounding The Alternator ...............

Inside Front Cover Section 2 — Operating Instructions

inside Front Cover

ets...
Volt

Volt,

, 2

,3

........4

, 25-28

.,5

,.5

.7

. 8

,.9
,.9

10
10
10

11

11

12

Do and Don’t Chart...... .......................
Before Starting the Engine.......... ........

Starting the Engine......................... .....
Stopping the Engine............. ...............
Wattage and Power......... ...... .............

Using the 120 Volt, 15 Amp Outlets ..
Using the 120 Volt, 30 Amp Outlet___
Using the 240 Volt, 20 Amp Outlet___
Don’t Overload the Alternator.............
Motor Starting Requirements...............

Charging a Battery............................. .

Section 3 — Preventive Maintenance

Maintenance Chart........ .....................

General Inspection ............................ .
Change Oil .........................................
Service Air Cleaner.............................

Inspect 30 Amp Fuse.........................

Spark Plugs..........................................
Clean Fuel Tank...................................

Inspect Cooling Fins............................
De-Carbonize Muffler............. .
Replace Fuel Filter..............................
De-Carbonize Engine Cylinder Heads .

Storage ...............................................

13
14
15
16
16
16

16

17
17

17
18

,19

19

,20

21

,21

22

22

,22

23

,23

. 23

,23

SPECIFICATiONS

Model No.

580.326010

Wattage Capacity

4500 Watts Continuous (5600 watts momentary surge)

Voltage Output

120/240 Volts

K

o

Amperes (Maximum)

37,5 at 120 Volts -18.75 at 240 Volts

<

Frequency

60 Hertz at 1800 rpm

cc

Phase(s)

Single Phase

111

H

Driven Speed

1800 rpm

<

Voltage Regulation

Solid state "Voltage over Frequency” regulator maintains

2120 vofts (± 2%) at 60 Hz.

Electrical Outlets

(2^ 120 Volt, 15 Amp
(1)-120 Volt. 30 Amp
(1)-240 Volt, 20 Amp

Make and Model

Briggs & Stratton Model No. 401415

Horsepower

Approximately 1Ö H.P. at 1800 rpm

No. of Cylinders

2

Displacement

40 Cubic Inches (656 cc’s)

Ui

Governed Speed

1800 rpm

o

Fuel Tank Capacity

5 Gallons (18.925 Liters)

111

Recommended Fuel

Use clean, fresh NON-LEADED gasoline (Leaded, REGULAR grade

gasoline is an acceptable substitute)

Crankcase Oil
Capacity

3V2 Pints (1.65 Liters)

Spark Plug

Use Champion J*8, Auto-Lite A-71, or AC GC46

Set gap to ,,030 inch

Starting

Electric Ring Gear

Cooling System

Forced air (Centrifugal Blower Type)

Air Cleaner

Dry paper cartridge with oil foam pre-cleaner