SERVICE AIR CLEANER
Clean and re-oil Air Cleaner foam pre-cleaner at 3 month intervals or every 25 operating hours,
vi/hichever comes first. Service more often if operating under dirty or dusty conditions. Service
foam pre-cleaner as follows:
Remove cover nut and cover.
Remove foam pre-cfeaner by sliding it up
and off the paper cartridge.
A-Wash foam pre-cleaner in liquid
detergent and water.
B-Squeeze pre-cleaner dry.
C-Oil pre-cleaner with one ounce clean
engine oil.
D-Squeeze to distribute oil.
Assemble pre-cleaner to paper cartridge.
Install cover and cover nut. Turn cover nut
down tight.
Once yearly or every 100 hours of operation (whichever comes first), remove hex nut, cover plate,
and paper cartridge. Clean paper cartridge by tapping gently on a flat surface. If extremely dirty,
replace cartridge or wash cartridge in liquid detergent and water. Rinse cartridge until water re
mains clear. AIR DRY CARTRIDGE THOROUGHLY BEFORE USING.
INSPECT 30 AMP FUSE
The alternator is equipped with a battery charging circuit This circuit provides an automatic
“trickle" charge of 0 - 8 amps to the unit battery whenever the engine is running. The circuit is
protected by a 30 amp fuse. Inspect the fuse every 25 hours of operation, as follows:
1.
Push
in
on
Fuse
Cap
and
turn
counterclockwise to remove. Remove Fuse
Cap and 30 Amp Fuse.
2.
Inspect fuse element. If the element is
melted open, replace fuse. Use only an iden
tical 30 amp replacement fuse,
3. To install Fuse, insert metal end of fuse in
to Fuse Cap. Install Fuse and Fuse Cap into
Fuse Holder and rotate Cap clockwise while
pushing in on Fuse Cap.