beautypg.com

Phoenix Audio Spider MT505 SIP Administraor Guide User Manual

Page 17

background image

Call Waiting Activate

Enables the Call Waiting feature.



Disable



Enable (default)

Call Waiting SIP Reply

Determines the SIP response that is sent when another call
arrives while a call is in progress:



Ringing - 180 Ringing



Queued (default) - 182 Queued

Call Forward

Not implemented

Voice Over IP -> Services->Message Waiting Indication (MWI)

Activate

Enables the MWI feature.



Disable



Enable (default)

Voice Mail Number

Defines the extension number for accessing your voice mail
messages.
The valid value is up to 64 characters.

Subscribe to MWI

Determines whether the phone registers to an MWI server.
 Disable (default)
 Enable

MWI Server IP Address or Host Name

The IP address or host name of the MWI server.
The default value is 0.0.0.0.

MWI Server Port

The port number of the MWI server.
The valid range is 1024 to 65535. The default value is 5060.

MWI Subscribe Expiry Time

The interval between the MWI Subscribe messages.
The valid range is 0 to 86400. The default value is 3600.

Out of Service Behavior

Determines whether a reorder tone is played instead of a dial
tone if you configured a Registrar IP address and the
registration failed.



No Tone



Reorder Tone (default)

4.1.4.7 Voice Over IP -> Volume Settings

Ringer Volume

Ringing tone volume. This volume can be modified on-the-fly
by pressing the phone’s VOLUME UP or VOLUME DOWN
keys when the phone is in idle state, or when it rings for
incoming call.
The valid range is [0] to [-31] dB in steps of 1 dB, or Mute.

Speaker Volume

Speaker’s volume. This volume can be modified on-the-fly by
pressing the phone’s VOLUME UP or VOLUME DOWN keys
during a call, or while ringback indication is played.
The valid range is [0] to [-46] dB in steps of 2 dB, or Mute.

Microphone Volume

The volume of the voice signal sent from the device to the
other side during a call.
The valid range is [0] to [-46] dB in steps of 2 dB, or Mute.
The microphone can be Muted or unmuted on-the-fly by
pressing the Spider’s MUTE button during a call. On call
termination, the microphone’s mute state is reset to
unmuted.

4.1.5 Advanced Applications