Operator’s

Manual

Series 300

Automatic Transfer Switches

D design, 30 through 230 amp. sizes

DANGER is used in this manual to warn of high

voltages capable of causing shock, burns, or death.

WARNING is used in this manual to

warn of possible personal injury.

!

CAUTION is used in this manual to warn

of possible equipment damage.

!

An experienced licensed electrician must install the ATS.

30–200 amp. sizes

Refer to the outline and wiring drawings provided with

your ASCO Series 300 ATS for all installation details.

ASCO Series 300 Automatic Transfer Switches (ATSs) are

Listed under Underwriters Laboratories UL 1008 Standard

for Safety for Automatic Transfer Switches. ASCO Series

300s are also Listed under CSA C22.2 No. 178 Standard for

Automatic Transfer Switches. All control features are UL

Component Recognized, which assures that ASCO automatic

transfer switches meet OSHA Safety Requirements and will

be acceptable to electrical inspectors.
ASCO Series 300 Automatic Transfer Switches are suitable

for emergency and standby system applications. They meet

emergency system rating requirements as defined in

National Electrical Code (NEC) Article 700 and UL 1008.

Also, they are suitable for the requirements of NEC Article

517 – Health Care Facilities, NEC Article 701 – Legally

Required Standby Systems, NEC Article 702 – Optional

Standby Systems, NFPA 99 Health Care Facilities, and

NFPA 110 Emergency and Standby Power Systems.

Rating Label

Each automatic transfer switch contains a rating label to

define the loads and fault circuit withstand / closing ratings.

Refer to the label on the transfer switch for specific values.

Do not exceed the values on the rating label.

Exceeding the rating can cause personal injury

or serious equipment damage.

!

TABLE OF CONTENTS

section

INSTALLATION

1

. . . . . . . . . . . . . . . . . . . . . . . . . .

SEQUENCE OF OPERATION

2

. . . . . . . . . . . . .

TESTING & SERVICE

3

. . . . . . . . . . . . . . . . . . . .

ADJUSTMENTS

4

. . . . . . . . . . . . . . . . . . . . . . . . .

CONTROL FEATURES

5

. . . . . . . . . . . . . . . . . . .

INDEX

back cover

. . . . . . . . . . . . . . . . . . . . . . . . .