3.8.2.3 FUEL LEVEL
Measurement type
Resistance measurement by measuring voltage across sensor with a fixed current
applied
Arrangement
Differential resistance measurement input
Measurement current
10mA
Full scale
480Ω
Over range / fail
540Ω
Resolution
1%
Accuracy
+/-2% of full scale resistance (±9.6Ω) excluding transducer error
Max common mode
voltage
±2V
Display range
0-250%
3.8.2.4 FLEXIBLE SENSOR
NOTE : Flexible sensor is not available on DSE7200 series controllers
Measurement type
Resistance measurement by measuring voltage across sensor with a fixed current
applied
Arrangement
Differential resistance measurement input
Measurement current
10mA
Full scale
480Ω
Over range / fail
540Ω
Resolution
1%
Accuracy
+/-2% of full scale resistance (±9.6Ω) excluding transducer error
Max common mode
voltage
±2V
Display range
0-250%
3.8.3 CHARGE FAIL INPUT
Minimum voltage
0V
Maximum voltage
35V (plant supply)
Resolution
0.2V
Accuracy
± 1% of max measured voltage (±0.35V)
Excitation
Active circuit constant power output
Output Power
2.5W Nominal @12V and 24V
Current at 12V
210mA
Current at 24V
104mA