Description

Wilkerson Manual Dryers are intended to remove water vapor from the

compressed air system. Atmospheric dew points as low as -100°F (-

73°C) are achievable when operated within rated unit specifications.

General Safety Information

Release all air pressure from intended airline before installation.

• Install unit in air line before opening desiccant container. After unit

installation, add desiccant following steps in desiccant replacement

instructions on page 2.

• Always make sure bowl, bowl guard, and clamp ring are in place

and the clamp ring is securely locked before pressurization.

• DO NOT exceed the pressure and temperature ratings as shown in

the specifications.

• Follow all local, state and

federal EPA, OSHA, and

similar codes regarding

disposal of old desiccant.

Installation

1.

Refer to WARNING (on page 6).

2. Install as close as possible to the point where the air is being used.
3. Install unit with the airflow going in the direction of the arrow. For the

X04, install with airflow entering at the bottom center port of the 4-way

valve and exiting at the center port of the shuttle valve.

4. Install unit on air line before opening desiccant container. After

installation, add desiccant. Shake and tap bowl while filling to settle

desiccant. Fill Model X25 and X03/X04 to 1/8" below inner shoulder

of bowl. Fill Model X06 bowl to within 1/2" of top.

5. Replace bowl and bowl guard, or metal bowl, and clamp ring onto

the unit. Be sure clamp ring is securely locked in place before

pressurizing unit.

6. Most manual desiccant dryer users will achieve optimal results when

installing the dryer as close to the equipment or process being protected

as possible in the compressed air system. Most users, especially those

with high quality air requirements, should protect their system and the

manual dryer with one or more of the following types of components:

Please see page 4 for exact model recommendations.
• Liquid Separator:
Should be used prior to the manual desiccant

dryer in any system where large slugs of liquid water are anticipated.

The manual desiccant dryer silica gel or mole sieve can be destroyed

by large amounts of liquid moisture. Most systems which have an

aftercooler and separator, and/or a refrigerated air dryer, will not

require a liquid separator. An alternative is to use a particulate filter/

separator, described below.

• Particulate Filter/Separator: Should be used prior to the manual

desiccant dryer in any system where significant amounts of dirt,

pipe scale, etc, and/or liquid water, is present, in order to prevent

clogging the manual dryer or harming the desiccant. A particulate

filter/separator should be used prior to a coalescing filter to extend

the life of the coalescing element.

Specifications

X06

X03 Plastic Bowl

X03 Metal Bowl

X04

X25 Metal Bowl

Maximum Pressure

150 psig (10.3 bar)

150 psig (10.3 bar)

150 psig (10.3 bar)

150 psig (10.3 bar)

150 psig (10.3 bar)

Maximum Temperature

125°F (52°C)

125°F (52°C)

150°F (66°C)

125°F (52°C)

150°F (66°C)

Atmospheric Dewpoint*

000 Model: Silica Gel

U00 Model: 4A Molecular

Sieve

000 Model:

-45°F (-43°C)

U00 Model:

-100°F (-73°C)

000 Model:

-45°F (-43°C)

U00 Model:

-100°F (-73°C)

M00 Model:

-45°F (-43°C)

MU0 Model:

-100°F (-73°C)

000 Model:

-45°F (-43°C)

U00 Model:

-100°F (-73°C)

000 Model:

-45°F (-43°C)

U00 Model:

-100°F (-73°C)

Maximum Continuous Airflow*

5 scfm (2.3 dm

3

/s)

10 scfm (4,7 dm

3

/s)

10 scfm (4.7 dm

3

/s)

10 scfm (4.7 dm

3

/s)

25 scfm (11.8 dm

3

/s)

Total Airflow*

600 scf (283 dm

3

)

4400 scf (2076 dm

3

)

4400 scf (2076 dm

3

)

4400x2 scf (2076x2 dm

3

) 11,000 scf (5191 dm

3

)

Total Min. of Operation @

Max Continuous Airflow

120 min.

440 min.

440 min.

880 min.

440 min.

Unit Weight With Desiccant

1.13 lbs. (0.51 kg)

7.4 lbs. (3.4 kg)

6.8 lbs. (3.1 kg)

15.0 lbs. (6.8 kg)

11.2 lbs. (5.1 kg)

# of Desiccant Bags/Charge

1 Bag **

2 Bags ***

2 Bags***

4 Bags***

5 Bags***

Pipe Connections

1/4" NPT (BSPP)

1/4", 1/2" NPT (BSPP) 1/4", 1/2" NPT (BSPP)

1/4", 1/2" NPT (BSPP)

1/2" NPT (BSPP)

*With Dry Desiccant at 100 psig (7 bar) and 70°F (21°C)

** Each bag weighs .25 lbs. (.11kg)

*** Each bag weighs .88 lbs. (.40kg)

Installation & Service Instructions
83-050-000
Manual Desiccant Dryer Models

X06, X03, X04, and X25 with
Variations and Accessories
ISSUED: April, 2013
Supersedes: April, 2007

Doc. #83050000, EN #130200, Rev. 4

!

WARNING

To avoid unpredictable system behavior that can cause personal injury

and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to this

product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how

pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical supplies

(when necessary) should be connected and the product tested for

proper function and leakage. If audible leakage is present, or the

product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered by

paint, etc. If masking is not possible, contact your local representative

for replacement labels.

Safety Guide

For more complete information on recommended application guidelines, see the
Safety Guide section of Pneumatic Division catalogs or you can download the
Pneumatic Division Safety Guide at: www.wilkersoncorp.com