Wilkerson V12 User Manual
Operation, Introduction, Application limits
2. Install valve so that air flow is in the direction of arrow.
Installation must be upstream from devices it is to service
(e.g. lubricator, valve, cylinder, or tool), and mounted closely
to these devices. Mounting may be in any position.
3. Installing a filter upstream of the valve (as close to the unit
as possible) will provide added protection against rust, pipe
scale, and other foreign matter.
Operation
CAUTION: Shackle size of lock must be 7.1mm
(9/32 inch) in diameter or smaller.
Lockout Operation - With handle turned across the valve body
the inlet port is blocked. Outlet port is open to exhaust. A padlock
may be inserted through one of the two holes in the handle.
Normal Flow Operation - Turn handle to be in line with the
body to open valve. Inlet port is open to supply downstream air.
Introduction:
Follow these instructions when installing, operating, or servicing
the product.
Application Limits
These products are intended for use in general purpose
compressed air systems only and must not be subjected to
conditions outside of the following ratings:
Operating Pressure:
kPa
PSIG
bar
Maximum Inlet Pressure:
1720
250
17.2
Ambient Temperature Range: 0°C to 80°C (32°F to 175°F)
ANSI Symbol
1 - Inlet
2 - Outlet to System
3 - Exhaust
Lockout Valve - 2-Position; 3-Way
Installation
1. The valve should be installed with reasonable accessibility
for service whenever possible. Keep pipe or tubing lengths to
a minimum with inside clean and free of dirt and chips. Pipe
joint compound should be used sparingly and applied only to
the male pipe - never into the female port. Do not use PTFE
tape to seal pipe joints - pieces have a tendency to break off
and lodge inside the unit, possibly causing malfunction.
2
3
1
!
Lock Hole
Lock Hole
Installation & Service Instructions
83-961-000
V12 Modular Lockout Valves
ISSUED: May, 2005
Supersedes: July, 2004
Doc.# 83961000, ECN# 050500, Rev. 3
Richland, MI 49083
Tel: (269) 629-5000
WARNING
To avoid unpredictable system behavior that can cause personal injury
and property damage:
•
Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.
•
Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.
•
Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.
•
Medium must be moisture-free if ambient temperature is below
freezing.
•
Service according to procedures listed in these instructions.
•
Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
•
After installation, servicing, or conversion, air and electrical supplies
(when necessary) should be connected and the product tested for
proper function and leakage. If audible leakage is present, or the
product does not operate properly, do not put into use.
•
Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.
!
WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from The Company, its subsidiaries
and authorized distributors provide product and/or system options for further
investigation by users having technical expertise. It is important that you
analyze all aspects of your application, including consequences of any failure
and review the information concerning the product or systems in the current
product catalog. Due to the variety of operating conditions and applications
for these products or systems, the user, through its own analysis and testing,
is solely responsible for making the final selection of the products and
systems and assuring that all performance, safety and warning requirements
of the application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by The
Company and its subsidiaries at any time without notice.
EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION
IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE
PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.
!