Wilkerson X05 User Manual
Page 2
INSTALLATION
1.Refer to the warning.
2.Install downstream of dryer or where required.
3.Install the unit with the airflow in direction of arrow.
4.Silica gel changes from dark blue to pink to indicate 10% relative
humidity, reactivating itself when dry air flows through unit.
MAINTENANCE
1. Under normal conditions this unit will be trouble free with no mainte-
nance required.
2. The silica gel will require changing if oil or other contamination enters the
unit.
A. TO DISASSEMBLE-shut off air, vent pressure from unit and unscrew
bowl.
B. Clean bowl with clean dry cloth only.
C. Fill bowl with 25 grams of color-indicating silica gel and screw onto
bowl.
3. DO NOT PRESSURIZE UNIT unless bowl is secured in place.
REPAIR KITS AND REPLACEMENT PARTS
Silica Gel (0.67) ....................................................................DRP-95-303
Plastic Bowl Unit ...................................................................GRP-95-857
Metal Bowl Guard .................................................................GRP-96-309
RESTRICTION (if necessary)
TO ASSURE AT LEAST 1 scfm
THROUGH INDICATOR
MOISTURE
INDICATOR
AIRFLOW
DRYER TO BE
MONITORED