beautypg.com

Wilkerson Dial-Air Regulator Repair Kits User Manual

Introduction, Installation, Maintenance

background image

!

Introduction:

Follow these instructions when installing, operating, or servicing
the product.

Installation

1. Refer to warning above.

2. Maximum pressure rating is 300 PSIG (21 bar).

Temperature range is 32°F to 150° (0°C to 65.5°C).

3. Install unit as close as possible to where regulated air is

needed.

4. Install unit with the air flowing through the body in the

indicated direction.

5. Install 1/4" pipe or tubing from the pilot regulator to the 1/4"

NPT inlet in top of cover. (See installation diagram below.)

6. A pressure gauge is not required; however, a gauge may

be attached to one of the 1/4" NPT female cross ports by
removing one of the pipe plugs. These ports may also be
used as regulated air outlets.

7. Install an air filter before the regulator. Filter must be sized

so it will adequately handle the flow of air to the device
whose pressure is being regulated.

Maintenance

1. TO DISASSEMBLE: Shut off air and vent air lines on both

sides of the regulator. Remove retaining ring and lift cover
and piston out of body. Remove bottom plug (R31) or
plate (R41) and pull out main valve.

2. TO ASSEMBLE: Relubricate all seals and sealing surfaces

with Parker O-Lube. Assemble main valve, main valve
spring, and bottom plug or plate. Insert piston into body
and install cover and retaining ring. Ensure retaining ring is
fully locked into retaining groove in body.

3. IF UNIT WILL NOT REGULATE TO PRESSURE, OR IF

PRESSURE DROP BECOMES EXCESSIVE:

A. Check pilot air line for leaks, crimps, etc., and the pilot

regulator for proper operation.

B. Remove bottom plug or plate and main valve. Clean and

check seals valves and valve seats for wear and damage.
Relubricated o-rings with Parker O-Lube. If main valve is
worn or damaged, install the proper repair kit.

CAUTION: ENSURE RETAINING RING IS FULLY
LOCKED INTO RETAINING GROOVE IN BODY.
Failure to properly seat retaining ring into groove
in body could allow separation of cover assembly
from body when pressurized, causing personal
injury or damage.

Pilot Regulator
R11

Supply Line
to Pilot
Regulator
(1/4" typical)

Prefilter

Inlet

Outlet

Air Flow

Gauge

Repair Kits for R21, R31, R41 on Page 2

Typical Installation for

R21, R31, R41 Remote Controlled Regulators

!

WARNING

To avoid unpredictable system behavior that can cause personal injury
and property damage:

Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.

Disconnect air supply and depressurize all air lines connected to
this product before installation, servicing, or conversion.

Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.

Medium must be moisture-free if ambient temperature is below
freezing.

Service according to procedures listed in these instructions.

Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

After installation, servicing, or conversion, air and electrical
supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.

Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.

!

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE
PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY
DAMAGE.
This document and other information from The Company, its subsidiaries
and authorized distributors provide product and/or system options for further
investigation by users having technical expertise. It is important that you
analyze all aspects of your application, including consequences of any
failure and review the information concerning the product or systems in the
current product catalog. Due to the variety of operating conditions and
applications for these products or systems, the user, through its own
analysis and testing, is solely responsible for making the final selection of
the products and systems and assuring that all performance, safety and
warning requirements of the application are met.
The products described herein, including without limitation, product features,
specifications, designs, availability and pricing, are subject to change by
The Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

Installation & Service Instructions
83-965-000

Remote Controlled Regulators

ISSUED: July, 2004
Supersedes: April, 2004

Doc. #83-965-000, Rev. 5

Richland, MI 49083

Tel: (269) 629-5000

!

WARNING

Product rupture can cause serious injury.

Do not connect regulator to bottled gas.

Do not exceed maximum primary pressure rating.