beautypg.com

Wilkerson SR2 User Manual

Safety guide, Introduction, Application limits

background image

Relieving Regulator

Adjustable

Non-Relieving Regulator

Adjustable

Introduction

Follow these instructions when installing, operating, or servicing the
product.

Application Limits

These products are intended for use in general purpose compressed
air systems only.
Operating Pressure:

kPa

PSIG

bar

Maximum Inlet Pressure

2068

300

21.0

Operating Temperature Range:
Plastic Knob

0°F to 150°F (18°C to 66°C)

Stainless Steel Knob

0°F to 180°F (18°C to 82°C)

Option “L” Minimum Operating Temperature*: -40°F (-40°C)

Note: Air must be dry enough to avoid ice formation at temperatures

below 32°F (0°C).

*Note: “Low Temperature” option is intended for applications where the

ambient temperature may be down to -40° C/F. Air supply must be free
of moisture to prevent ice formation and malfunction of units. These
units contain EPDM seals. Make sure any oils in the airstream are
compatible.

Richland, MI 49083

Tel: (269) 629-5000

WARNING

To avoid unpredictable system behavior that can cause personal injury

and property damage:

• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected to this

product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,

and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is below

freezing.

• Service according to procedures listed in these instructions.
• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how

pneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical supplies

(when necessary) should be connected and the product tested for

proper function and leakage. If audible leakage is present, or the

product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered by

paint, etc. If masking is not possible, contact your local representative

for replacement labels.

!

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE

PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED

ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY

DAMAGE.
This document and other information from The Company, its subsidiaries

and authorized distributors provide product and/or system options for further

investigation by users having technical expertise. It is important that you

analyze all aspects of your application, including consequences of any failure

and review the information concerning the product or systems in the current

product catalog. Due to the variety of operating conditions and applications for

these products or systems, the user, through its own analysis and testing, is

solely responsible for making the final selection of the products and systems

and assuring that all performance, safety and warning requirements of the

application are met.
The products described herein, including without limitation, product features,

specifications, designs, availability and pricing, are subject to change by The

Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION

IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS.

CONTACT YOUR LOCAL REPRESENTATIVE.

!

WARNING

Product rupture can cause serious injury.

Do not connect regulator to bottled gas.

Do not exceed maximum primary pressure rating.

!

Installation

1. The regulator should be installed with reasonable accessibility for

service whenever possible - repair service kits are available. Keep
pipe and tubing lengths to a minimum with inside clean and free
of dirt and chips. Pipe joint compound should be used sparingly
and applied only to the male pipe - never into the female port. Do
not use PTFE tape to seal pipe joints - pieces have a tendency to
break off and lodge inside unit, possibly causing malfunction.

2. Install regulator so that air flow is in the direction of arrow.

Installation must be upstream (high pressure) side and as close to
the devices it is to service (valve, cylinder, tool, etc.) as possible.
Mounting may be in any position.

3. Gauge ports are located on both sides of the regulator body for

your convenience. It is necessary to install a gauge or pipe plugs
into each port during installation.

4. For protection against rust, pipe scale, and other foreign matter,

install a filter on the upstream (high pressure) side as close to the
regulator as possible.

Operation

1. Before turning on the air supply:
1A. On SR1, disengage the adjusting knob by pulling upward. Turn

adjusting knob counterclockwise until the compression is released
from the pressure control spring.

1B. On SR2, push down on the adjusting knob while turning knob

counterclockwise until the compression is released from the
pressure control spring. (Knob is locked when up.)

2. Then turn on air supply and adjust regulator to desired secondary

pressure by turning adjusting knob clockwise. This permits
pressure to build up slowly, preventing any unexpected operation
of the valve, cylinders, tools, etc., attached to the line. Adjustment

Installation & Service Instructions
83-951-000

SR1 & SR2 Regulators

ISSUED: May, 2008
Supersedes: August, 2006