Maintenance, Repair kits and replacement parts, Accessories – Wilkerson M16 User Manual
Page 2

MAINTENANCE
1. The element operates effectively when it is saturated. The element's
useful life will end only when the resistance to flow becomes too high
or the maximum permissible pressure is reached. The element cannot
be cleaned or reused and must be replaced at the end of its useful
life.
2. IF THE UNIT HAS A MANUAL DRAIN, drain the unit once every 8
hours. IF UNIT IS EQUIPPED WITH AN AUTOMATIC MECHANICAL
DRAIN, clean the screen around the drain seat each time the element
is cleaned or replace it by removing the nut and removing the drain
assembly. Clean screen by blowing off with air blow gun.
3. When bowl becomes dirty, replace the bowl or clean by wiping with a
dry, clean cloth.
4. Before placing the unit in service, make sure that the bowl and bowl
guard are reinstalled, and securely locked in place.
REPAIR KITS AND REPLACEMENT PARTS
Bowl O-Ring Kit (Fluorocarbon) ...........................................GRP-95-009
Replacement Elements:
Type D Element Kit ..........................................................MXP-95-987
Type C Element Kit ..........................................................MTP-95-548
Type B Element Kit ..........................................................MTP-95-988
Drains:
Automatic Mechanical Drain (w/ Fluorocarbon Seals) .....GRP-95-981
Automatic Mechanical Drain ............................................GRP-95-973
Flex-Drain™ .................................................................... FRP-95-610
Transparent Plastic Bowl Assemblies:
Flex-Drain™ .................................................................... FRP-95-017
with Flex-Drain™and bowl guard..................................... FRP-95-014
with Auto. Mech. Drain and bowl guard ........................... FRP-95-015
Bowl Guard Kit .....................................................................GRP-95-013
Metal Bowl Assemblies:
with Petcock and Viton O-ring ......................................... FRP-95-178
with Auto. Mech. Drain (Fluorocarbon seals) ................... FRP-95-950
Brass Petcock Kit ................................................................ GRP-95-182
Differential Pressure Indicator ............................................. DP2-01-000
ACCESSORIES
Bracket Kit ........................................................................... GPA-95-016
O-ring
Differential
Pressure
INdicator
Gasket
Gasket
Body
Filter
Element
Type B or
Type C
Flex Drain™
(Plastic Bowls
Only)
Transparent
Bowl
Bowl
Guard
Nut
Nut
Insert
Retainer
Petcock
Metal
Bowl
O-ring
O-ring
O-ring
Bowl
INsert
O-ring
Automatic
Mechanical
Drain
Automatic
Mechanical
Drain
Plate
Body
Filter
Element
Type D