beautypg.com

Maintenance – Vogelzang VG450ELGB User Manual

Page 14

background image

Page 14

/

VG450EL FrontiErsman™

www.vogelzang.com

VGZ-014 / 20120424.0

mAINTENANCE

height requirements listed in the Chimney

Connection section of the manual have been

met. The physics that link chimney height with

draft creation are vital to the proper operation

of the stove. Failure to meet each of these

minimum requirements will have an adverse

affect on draft. Avoid long horizontal runs

or multiple elbows. Use stove cement to seal

joints in the connector pipe section. Regularly

clean the chimney, connector pipe, rain cap, and

spark arrestor screen. Creosote build up can

reduce the chimney draw and possibly create

a chimney fire.

5. Temporarily out of Operation

After the fire has burned out, open the air con-

trol to its fully open position. This will allow

warm room air to enter the chimney and keep

it as warm as possible until the stove is used

again.

For assistance involving chimney draft issues, con-
tact a knowledgeable licensed heating and cooling
contractor in your area. For questions regarding
manufactured chimney, contact the manufacturer
of the chimney.

nOTe: a DraFT reaDInG OF 0.05 TO 0.06 w.C.
(waTer COluMn) Is requIreD FOr PrOPer
BurnInG OF ThIs sTOVe.

Glass Care

CauTIOn: DO nOT OPeraTe wITh CraCkeD
Or BrOken Glass.

Periodic cleaning of glass will be necessary to

prevent accumulations of ash. Acidic ash buildup
can eventually etch and weaken glass. Creosote
accumulations should burn off during hot fires. The
following usage and safety tips should be observed:

1. Inspect the glass regularly for cracks and

breaks. If you detect a crack or break, extin-

guish the fire immediately and contact the

manufacturer for a replacement before re-firing

the stove.

2. Do not slam the door or otherwise impact the

glass. When closing doors, make sure that logs

or other objects do not protrude to impact the

glass.

3. Do not build fires against (or that might fall

against) the glass.

4. Do not clean the glass with materials that

may scratch (or otherwise damage) the glass.

Scratches on the glass can develop into cracks

or breaks during operation.

5. Never attempt to clean the glass while the unit

is hot; allow to dry thoroughly before reuse.

If deposits are not very heavy, normal glass

cleaners are adequate using a soft, non-abrasive

cleaning pad.

6. Never put substances which can ignite explo-

sively in the unit. Even small explosions in

confined areas can blow out the glass.

Glass rePlaCeMenT

warnInG: rePlaCe Glass OnlY wITh 5MM
hIGh TeMPeraTure CeraMIC Glass OF
The PrOPer sIze. DO nOT use suBsTITuTe
MaTerIals suCh as TeMPereD Glass
Or DOuBle ThICkness wInDOw Glass!
COnTaCT The sTOVe ManuFaCTurer FOr
rePlaCeMenT Glass.

Gasket and Glass cleaning products are avail-

able at local retail home centers. Manufacturers
of cleaning products include, A.W. Perkins Co.
(www.awperkins.com) or Rutland Products (www.
rutland.com).
Glass replacement Procedure:

1. Ensure appliance is not in operation and is

thoroughly cooled.

2. Remove screw and glass clips. (See parts list

and diagram.)

3. Remove glass from door frame.
4. If glass is broken, carefully remove and discard

each broken piece to avoid cuts. Discard win-

dow gasket. Replace window and gasket with

original factory replacement parts.

5. Replace new gasket starting at the bottom of

glass working along edges, being sure to center

gasket channel on glass.

6. Trim to length and butt ends together.
7. Perform replacement procedure in reverse order

after replacing glass and gasket.

8. When replacing glass into door, be sure not to

overtighten screws and clips.

DOOr GaskeT rePlaCeMenT

CauTIOn: DO nOT OPeraTe a sTOVe ThaT
Is MIssInG DOOr GaskeT MaTerIal. OVer
FIrInG anD unsaFe OPeraTInG COnDI-
TIOns MaY resulT.

After extensive use, the gasket material which

provides glass and door seal may lose it’s resiliency
and will need to be replaced. Inspect glass and door

This manual is related to the following products: