10.2. Infrared Wireless Receiver Installation Examples
The receiver's communications area differs depending on such environmental conditions as the ceiling height.
(Refer to p. 10 "Infrared Wireless Receiver Coverage Area.")
10.2.2. Installing 2 IR-510Rs
Note
Install these 6 m (19.69 ft) to 8 m (26.25 ft) apart
so that each receiver's communications area
overlaps with each other.
10.2.3. Installing 2 IR-520Rs
Note
Install these 6 m (19.69 ft) to 8 m (26.25 ft) apart
so that each receiver's communications area
overlaps with each other.
6 – 8 m
(19.69 – 26.25 ft)
Infrared wireless receiver's
communications area
IR-510R
18 m (59.06 ft)
10 m (32.81 ft)
15 m (49.21 ft)
15 m (49.21 ft)
12 m (39.37 ft)
12 m (39.37 ft)
IR-520R
6 – 8 m
(19.69 – 26.25 ft)
Infrared wireless receiver's
communications area
10.2.1. Installing 4 IR-500Rs and IR-520Rs
Note
In a rectangular room where the usage area is wider than the infrared receiver's communication distance,
install the receivers on the opposite side as well.
12 m (39.37 ft)
12 m (39.37 ft)
25 m (82.02 ft)
18 m (59.06 ft)
IR-500R
Infrared wireless receiver's
communications area